TRANSIENT THERMAL AND MECHANICAL RESPONSE OF WATER SUBJECT TO IONIZING-RADIATION

被引:14
作者
APFEL, RE [1 ]
SUN, YY [1 ]
NATH, R [1 ]
机构
[1] YALE UNIV,SCH MED,DEPT THERAPEUT RADIOL,NEW HAVEN,CT 06510
关键词
D O I
10.2307/3578432
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The ultrafast transient (10-14 to 10-12s) thermal and mechanical response of water subject to ionizing radiations of different linear energy transfers has been investigated in order to understand the initial events which lead to cell mutation and lethality. Based on computational fluid dynamics, the production of a 'thermal spike' around the trajectory of a charged particle and subsequent diffusion of deposited heat are calculated for particles with linear energy transfer (LET) of 4, 40, and 400 keV/μm. A radiation damage region (that is, the so-called 'thermal core') is identified, and the transient behavior of the thermal core is studied. The local and transient environment has a dimension of nanometers, a scale which is of critical interest in understanding mechanisms of radiation damage in cells. The radius of the thermal core, D(d), at temperatures (or internal energy density) of up to 1000 K, is observed to increase with LET, L, as D(d) (in nanometers) = C4 · L (in keV/μm)0.6, where, for example, C4 = 0.50 for T = 800°C.
引用
收藏
页码:124 / 132
页数:9
相关论文
共 36 条
[1]   SUPERHEATED DROP DETECTOR [J].
APFEL, RE .
NUCLEAR INSTRUMENTS & METHODS, 1979, 162 (1-3) :603-608
[2]   SUPERHEATED DROP NUCLEATION FOR NEUTRON DETECTION [J].
APFEL, RE ;
CHU, BT ;
MENGEL, J .
APPLIED SCIENTIFIC RESEARCH, 1982, 38 :117-122
[3]  
CHANG CX, 1985, RADIAT PROT DOSIM, V13, P215
[4]   CALCULATION OF INITIAL YIELDS OF SINGLE-STRAND AND DOUBLE-STRAND BREAKS IN CELL-NUCLEI FROM ELECTRONS, PROTONS AND ALPHA-PARTICLES [J].
CHARLTON, DE ;
NIKJOO, H ;
HUMM, JL .
INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 1989, 56 (01) :1-19
[5]   THE DEPOSITION OF ENERGY IN SMALL CYLINDRICAL TARGETS BY HIGH LET RADIATIONS [J].
CHARLTON, DE ;
GOODHEAD, DT ;
WILSON, WE ;
PARETZKE, HG .
RADIATION PROTECTION DOSIMETRY, 1985, 13 (1-4) :123-125
[6]  
CHATTERJEE A, 1985, RADIAT PROT DOSIM, V13, P137
[7]   MICRODOSIMETRIC STRUCTURE OF HEAVY-ION TRACKS IN TISSUE [J].
CHATTERJEE, A ;
SCHAEFER, HJ .
RADIATION AND ENVIRONMENTAL BIOPHYSICS, 1976, 13 (03) :215-227
[8]   THE MOVING FINITE-ELEMENT METHOD - APPLICATIONS TO GENERAL PARTIAL-DIFFERENTIAL EQUATIONS WITH MULTIPLE LARGE GRADIENTS [J].
GELINAS, RJ ;
DOSS, SK ;
MILLER, K .
JOURNAL OF COMPUTATIONAL PHYSICS, 1981, 40 (01) :202-249
[9]  
GOODHEAD DT, 1987, DOSIMETRY IONIZING R, V2, P1
[10]   SIMPLE 3-PARAMETER EQUATION OF STATE WITH CRITICAL COMPRESSIBILITY-FACTOR CORRELATION [J].
HORVATH, C ;
LIN, HJ .
CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1977, 55 (04) :450-456