VISIBLE DIODE-LASER INDUCED FLUORESCENCE DETECTION IN LIQUID-CHROMATOGRAPHY AFTER PRECOLUMN DERIVATIZATION OF THIOLS

被引:40
作者
MANK, AJG
MOLENAAR, EJ
LINGEMAN, H
GOOIJER, C
BRINKMAN, UAT
VELTHORST, NH
机构
[1] Department of General and Analytical Chemistry, Free University, NL-1081 HV Amsterdam
关键词
D O I
10.1021/ac00065a006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
New cyanine labels containing only a single active group for the chemical derivatization of thiols were synthesized in order to apply visible diode laser induced fluorescence (DIO-LIF) detection in conventional-size liquid chromatography (LC). 2-Mercaptobenzothiazole (MBT) was selected as test compound. The most appropriate label was CY5.4a-IA, a sulfonated dicarbocyanine with a iodoacetamide reactive group. The detection limit of labeled MBT in the LC-DIO-LIF system was 8 X 10(-12) M. The detection limit of MBT was 1 x 10(-9) M; lower concentrations are not labeled quantitatively. The injection repeatability was 1.0% (n = 6), the reaction repeatability was 3.0% (n = 6), and linearity was observed from 2.5 X 10(-9) to 1.0 x 10(-5) M. As an example, MBT-spiked river water and urine samples were derivatized with CY5.4a-IA and analyzed by LC-DIO-LIF. Hardly any interference was found. The method compares very favorably with existing techniques.
引用
收藏
页码:2197 / 2203
页数:7
相关论文
共 21 条
  • [1] AQUATIC ENVIRONMENTAL CHEMISTRY OF 2-(THIOCYANOMETHYLTHIO)BENZOTHIAZOLE AND RELATED BENZOTHIAZOLES
    BROWNLEE, BG
    CAREY, JH
    MACINNIS, GA
    PELLIZZARI, IT
    [J]. ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 1992, 11 (08) : 1153 - 1168
  • [2] DISPOSITION OF 2-MERCAPTOBENZOTHIAZOLE AND 2-MERCAPTOBENZOTHIAZOLE DISULFIDE IN RATS DOSED INTRAVENOUSLY, ORALLY, AND TOPICALLY AND IN GUINEA-PIGS DOSED TOPICALLY
    ELDAREER, SM
    KALIN, JR
    TILLERY, KF
    HILL, DL
    BARNETT, JW
    [J]. JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH, 1989, 27 (01): : 65 - 84
  • [3] CYANINE DYE LABELING REAGENTS FOR SULFHYDRYL-GROUPS
    ERNST, LA
    GUPTA, RK
    MUJUMDAR, RB
    WAGGONER, AS
    [J]. CYTOMETRY, 1989, 10 (01): : 3 - 10
  • [4] GALE DJ, 1977, AUST J CHEM, V30, P389
  • [5] HALTRICH WG, 1989, VOM WASSER, V73, P11
  • [6] HAUGLAND RP, 1992, MOL PROBES, P9
  • [7] DETERMINATION OF AMINO-ACIDS BY CAPILLARY ZONE ELECTROPHORESIS BASED ON SEMICONDUCTOR-LASER FLUORESCENCE DETECTION
    HIGASHIJIMA, T
    FUCHIGAMI, T
    IMASAKA, T
    ISHIBASHI, N
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (07) : 711 - 714
  • [8] HOFSTRAAT JW, 1993, MOL LUMINESCENCE SPE, P323
  • [9] SEMICONDUCTOR-LASER FLUORIMETRY IN THE NEAR-INFRARED REGION
    IMASAKA, T
    YOSHITAKE, A
    ISHIBASHI, N
    [J]. ANALYTICAL CHEMISTRY, 1984, 56 (07) : 1077 - 1079
  • [10] VISIBLE SEMICONDUCTOR-LASER FLUOROMETRY
    IMASAKA, T
    TSUKAMOTO, A
    ISHIBASHI, N
    [J]. ANALYTICAL CHEMISTRY, 1989, 61 (20) : 2285 - 2288