3D DETERMINATION OF THE INTRAVASCULAR VOLUME AND FLOW OF CORONARY-ARTERIES

被引:8
作者
GUGGENHEIM, N [1 ]
DORSAZ, PA [1 ]
DORIOT, PA [1 ]
SUILEN, C [1 ]
CHAPPUIS, F [1 ]
RUTISHAUSER, W [1 ]
机构
[1] UNIV HOSP GENEVA,CTR CARDIOL,CH-1211 GENEVA 14,SWITZERLAND
来源
INTERNATIONAL JOURNAL OF BIO-MEDICAL COMPUTING | 1994年 / 35卷 / 01期
关键词
3D-RECONSTRUCTION; CORONARY FLOW; CORONARY ARTERY;
D O I
10.1016/0020-7101(94)90045-0
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
An angiographic method for measurement of absolute coronary blood flow in patients was developed. It is based on 3D-reconstruction of the left or right coronary tree from digitized biplane coronary cineangiograms. The apparatus is presently composed of a 35-mm cinefilm projector with video camera and a 512 x 512 x 8-bits image array processor controlled by a VAX-11/750 computer. First, the parameters of the two projections are determined in the form of two 4 X 3 matrices from a pair of cineframes showing a 4-cm cube bearing markers. The cube is filmed after the coronary injection, with unchanged geometric configuration. The coronary arteries of interest are then 3D-reconstructed from a pair of cineframes showing them fully opacified. This allows the intravascular volumes needed for flow determination to be computed. Preliminary measurements in 12 patients showed that flow values obtained angiographically in the left descending coronary artery correlate well with the values measured simultaneously by thermodilution in the great cardiac vein (Q(angio) = 0.83 x Q(thermo) + 16.1 ml, r = 0.87, n = 29).
引用
收藏
页码:13 / 23
页数:11
相关论文
共 9 条
[1]  
PARKER DL, 1988, NEW DEV QUANTITATIVE, P215
[2]   INVIVO VALIDATION OF A THERMODILUTION METHOD TO DETERMINE REGIONAL LEFT-VENTRICULAR BLOOD-FLOW IN PATIENTS WITH CORONARY-DISEASE [J].
PEPINE, CJ ;
MEHTA, J ;
WEBSTER, WW ;
NICHOLS, WW .
CIRCULATION, 1978, 58 (05) :795-802
[3]   ORIGIN OF GREAT CARDIAC VEIN AND CORONARY SINUS DRAINAGE WITHIN LEFT-VENTRICLE [J].
ROBERTS, DL ;
NAKAZAWA, HK ;
KLOCKE, FJ .
AMERICAN JOURNAL OF PHYSIOLOGY, 1976, 230 (02) :486-492
[4]  
ROGERS DF, 1990, MATH ELEMENTS COMPUT, P87
[5]   BLOOD FLOW MEASUREMENT THROUGH SINGLE CORONARY ARTERIES BY ROENTGEN DENSITOMETRY .1. A COMPARISON OF FLOW MEASURED BY A RADIOLOGIC TECHNIQUE APPLICABLE IN INTACT ORGANISM AND BY ELECTROMAGNETIC FLOWMETER [J].
RUTISHAU.W ;
BUSSMANN, WD ;
NOSEDA, G ;
MEIER, W ;
WELLAUER, J .
AMERICAN JOURNAL OF ROENTGENOLOGY RADIUM THERAPY AND NUCLEAR MEDICINE, 1970, 109 (01) :12-&
[6]  
SIMON R, 1986, ANGIOCARDIOGRAPHY CU, P374
[7]  
SMITH HC, 1979, BIOMED TECH, V24, P156
[8]   COMPUTERIZED IMAGE-ANALYSIS FOR QUANTITATIVE MEASUREMENT OF VESSEL DIAMETER FROM CINEANGIOGRAMS [J].
SPEARS, JR ;
SANDOR, T ;
ALS, AV ;
MALAGOLD, M ;
MARKIS, JE ;
GROSSMAN, W ;
SERUR, JR ;
PAULIN, S .
CIRCULATION, 1983, 68 (02) :453-461
[9]   MEASUREMENT OF SYSTOLIC AND DIASTOLIC FLOW-RATES IN THE CORONARY-ARTERY SYSTEM BY X-RAY DENSITOMETRY [J].
SPILLER, P ;
SCHMIEL, FK ;
POLITZ, B ;
BLOCK, M ;
FERMOR, U ;
HACKBARTH, W ;
JEHLE, J ;
KORFER, R ;
PANNEK, H .
CIRCULATION, 1983, 68 (02) :337-347