GAS PERMEATION AND PRECONCENTRATION IN THE FLOW-INJECTION DETERMINATION OF ACID-AVAILABLE CYANIDE IN WASTE-WATER

被引:29
作者
KUBAN, V [1 ]
机构
[1] MASARYK UNIV, DEPT ANALYT CHEM, CS-61137 BRNO, CZECHOSLOVAKIA
关键词
FLOW SYSTEM; SPECTROPHOTOMETRY; CYANIDE; GAS PERMEATION; MEMBRANE SEPARATION; PRECONCENTRATION; WATERS;
D O I
10.1016/0003-2670(92)85073-F
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The determination of cyanide based on the reaction with highly selective sodium isonicotinate-3-methyl-1-phenyl-2-pyrazolin-5-one was optimized and compared with other spectrophotometric methods based on Konig's reaction. A reaction mechanism is proposed. The method, based on the formation of an intermediate product, allows a fast and highly sensitive determination of cyanide ions at concentrations from units to hundreds of mu-g l-1. The sampling frequency is 20 h-1 and the detection limit is 3-mu-g l-1 when 2.0 ml of sample are used. Most interferences, including those of CNS-, are eliminated by discrimination of mass transport through a non-porous silicone-rubber membrane.
引用
收藏
页码:45 / 52
页数:8
相关论文
共 55 条
[1]  
ALDRIDGE WN, 1945, ANALYST, V70, P474
[2]   POTENTIOMETRIC FLOW-INJECTION DETERMINATION OF COPPER COMPLEXING INORGANIC ANIONS WITH A COPPER WIRE INDICATOR ELECTRODE [J].
ALEXANDER, PW ;
HADDAD, PR ;
TROJANOWICZ, M .
ANALYTICAL CHEMISTRY, 1984, 56 (13) :2417-2422
[3]  
BARK LS, 1964, TALANTA, V11, P471
[4]  
BARK LS, 1964, TALANTA, V11, P621
[5]   CONTINUOUS MONITORING DEVICE FOR THE COLLECTION OF 23 VOLATILE ORGANIC PRIORITY POLLUTANTS [J].
BLANCHARD, RD ;
HARDY, JK .
ANALYTICAL CHEMISTRY, 1986, 58 (07) :1529-1532
[6]   SPECTROPHOTOMETRIC DETERMINATION OF CYANIDE WITH PYRIDINE AND 4,4'-DIAMINOSTILBENE-2,2'-DISULPHONIC ACID [J].
CASASSAS, E ;
RUBIO, R ;
RAURET, G .
ANALYST, 1984, 109 (09) :1159-1163
[7]   FLOW-THROUGH SENSOR FOR THE FLUOROMETRIC-DETERMINATION OF CYANIDE [J].
CHEN, DH ;
DECASTRO, MDL ;
VALCARCEL, M .
TALANTA, 1990, 37 (11) :1049-1055
[8]  
CUI H, 1984, HUANJING HUAXUE, V3, P48
[9]  
DURST RA, 1977, ANAL LETT, V10, P961
[10]   SEQUENTIAL FLOW-INJECTION DETERMINATION OF CYANIDE AND WEAK METAL CYANIDE COMPLEXES WITH FLOW-THROUGH HETEROGENEOUS MEMBRANE ELECTRODES [J].
FIGUEROLA, E ;
FLORIDO, A ;
AGUILAR, M ;
DEPABLO, J ;
ALEGRET, S .
ANALYTICA CHIMICA ACTA, 1988, 215 (1-2) :283-288