EXPLANATION OF HIGH-FREQUENCY PHASE-SHIFT IN AC IMPEDANCE MEASUREMENTS FOR COPPER IN LOW-CONDUCTIVITY MEDIA

被引:14
作者
FENG, YQ
ZHOU, GD
CAI, SM
机构
[1] BEIJING UNIV,DEPT CHEM,BEIJING 100871,PEOPLES R CHINA
[2] SHANGHAI INST ELECT POWER,DEPT THERMAL POWER ENGN,ELECTROCHEM RES GRP,SHANGHAI 200090,PEOPLES R CHINA
关键词
D O I
10.1016/0013-4686(91)85319-3
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The high-frequency phase shift is caused by the salt bridge, not by the sce itself. The resistance and the capacitance is believed to occur in the contact region between the low-conductivity solution and the tip of Luggin capillary.
引用
收藏
页码:1093 / 1094
页数:2
相关论文
共 2 条
[1]   MINIMIZATION OF HIGH-FREQUENCY PHASE-SHIFTS IN IMPEDANCE MEASUREMENTS [J].
MANSFELD, F ;
LIN, S ;
CHEN, YC ;
SHIH, H .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1988, 135 (04) :906-907
[2]  
ZHOU G, 1990, BOSHOKU GIJUTSU, V39, P361