EVALUATION OF VENTRICULAR DIASTOLIC FUNCTION IN NORMAL-CHILDREN USING EQUILIBRIUM RADIONUCLIDE ANGIOGRAPHY

被引:3
作者
AKAGI, T [1 ]
GREEN, M [1 ]
BENSON, LN [1 ]
ASH, J [1 ]
GILDAY, DL [1 ]
FREEDOM, RM [1 ]
机构
[1] HOSP SICK CHILDREN,DEPT PEDIAT,DIV CARDIOL,555 UNIV AVE,TORONTO M5G 1X8,ONTARIO,CANADA
关键词
D O I
10.1097/00006231-199213080-00006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Twenty children, aged 10.3 +/- 4.5 (3.3 to 17.5) years, were studied by equilibrium radionuclide angiography to establish a normal range for diastolic parameters. Ejection fraction (EF), peak ejection rate (PER) and time to peak ejection rate (TPER), peak filling rate (PFR) and time to peak filling rate (TPFR) were obtained from ventricular time-activity curves and their first derivative curves, and PFR and TPFR were considered as the diastolic parameters. Normal ranges obtained were as follows: EF, 60 +/- 8%; PER, 3.73 +/- 0.70 EDV-1; TPER, 109 +/- 25 ms; PFR, 3.84 +/- 0.51 EDVs-1; TPFR, 136 +/- 21 ms. There were significant correlations between PER and EF (P < 0.001), PFR and EF (P < 0.05), while age and heart rate had no influence upon these variables. Such normal ranges will be useful for evaluation of systolic and diastolic function in children with heart disease.