AN INTERCOMPARISON OF SAMPLING TECHNIQUES FOR NICOTINE IN INDOOR ENVIRONMENTS

被引:33
作者
CAKA, FM
EATOUGH, DJ
LEWIS, EA
TANG, HM
HAMMOND, SK
LEADERER, BP
KOUTRAKIS, P
SPENGLER, JD
FASANO, A
MCCARTHY, J
OGDEN, MW
LEWTAS, J
机构
[1] BRIGHAM YOUNG UNIV,DEPT CHEM,PROVO,UT 84602
[2] UNIV MASSACHUSETTS,SCH MED,DEPT FAMILY & COMMUNITY MED,WORCESTER,MA 01655
[3] YALE UNIV,JOHN B PIERCE FDN,NEW HAVEN,CT 06519
[4] YALE UNIV,SCH MED,NEW HAVEN,CT 06519
[5] HARVARD UNIV,SCH PUBL HLTH,BOSTON,MA 02115
[6] RJ REYNOLDS TOBACCO CO,WINSTON SALEM,NC 27102
[7] US EPA,RES TRIANGLE PK,NC 27711
关键词
D O I
10.1021/es00078a007
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A study using several types of sampling systems was conducted in the chamber facility at the Pierce Laboratory to compare the determination of nicotine in environmental tobacco smoke generated by volunteer smokers. The sampling systems used included filter packs, annular denuders, sorbent beds, and passive samplers. Total nicotine determined by the various sampling systems was generally in good agreement. Agreement among samplers was also generally good for gas-phase nicotine. The most notable exception was the determination of nicotine with a stainless steel passive sampler where the results were low due to adsorption of nicotine by the sampler. Agreement, but with poor precision, was seen for the determination of particulate-phase nicotine with a Tenax microtube sorbent sampling system and two different annular denuder systems. However, loss of particulate nicotine to the gas phase occurred during sampling with the filter pack system, and determination of particulate-phase nicotine by these systems was in error. Because greater than 95% of the nicotine was in the gas phase, this loss of particulate nicotine did not significantly affect the determination of gas-phase nicotine with a filter pack sampling system. © 1990, American Chemical Society. All rights reserved.
引用
收藏
页码:1196 / 1203
页数:8
相关论文
共 47 条
  • [1] CURVALL M, 1987, INDOOR AIR 87, V2, P57
  • [2] CURVALL M, 1987, 4TH P INT C IND AIR
  • [3] THE CHEMICAL-COMPOSITION OF ENVIRONMENTAL TOBACCO-SMOKE .3. IDENTIFICATION OF CONSERVATIVE TRACERS OF ENVIRONMENTAL TOBACCO-SMOKE
    EATOUGH, DJ
    BENNER, CL
    TANG, H
    LANDON, V
    RICHARDS, G
    CAKA, FM
    CRAWFORD, J
    LEWIS, EA
    HANSEN, LD
    EATOUGH, NL
    [J]. ENVIRONMENT INTERNATIONAL, 1989, 15 (1-6) : 19 - 28
  • [4] EATOUGH DJ, 1988, P EPA APCA S MEASURE, P739
  • [5] EATOUGH DJ, 1989, ENVIRON SCI TECHNOL, V23, P688
  • [6] EATOUGH DJ, 1988, 1988 P ACPA SPEC C I, P183
  • [7] EATOUGH DJ, 1986, 79TH P ANN M AIR POL
  • [8] EUDY L, 1987, 4TH P INT C IND AIR
  • [9] EUDY L, 1987, INDOOR AIR 87, V2, P126
  • [10] EUDY LW, 1986, 79TH P ANN M AIR POL