FEASIBILITY OF AMBULATORY, CONTINUOUS 24-HOUR FINGER ARTERIAL-PRESSURE RECORDING

被引:247
作者
IMHOLZ, BPM
LANGEWOUTERS, GJ
VANMONTFRANS, GA
PARATI, G
VANGOUDOEVER, J
WESSELING, KH
WIELING, W
MANCIA, G
机构
[1] UNIV AMSTERDAM, ACAD MED CTR,DEPT INTERNAL MED,ROOM F4 257, MEIBERGDREEF 9, 1105 AZ AMSTERDAM, NETHERLANDS
[2] UNIV AMSTERDAM, ACAD MED CTR, TNO BIOMED INSTRUMENTAT, 1105 AZ AMSTERDAM, NETHERLANDS
[3] UNIV MILAN, CATTEDRA SEMIOT MED, I-20122 MILAN, ITALY
[4] UNIV MILAN, IST CLIN MED GEN & TERAPIA MED, I-20122 MILAN, ITALY
[5] OSPED MAGGIORE CA GRANDA, CTR FISIOL CLIN & IPERTENS, MILAN, ITALY
关键词
BLOOD PRESSURE DETERMINATION; EXERCISE; BLOOD PRESSURE MONITORS; MONITORING; PHYSIOLOGICAL; FEASIBILITY STUDIES; HYDROSTATIC PRESSURE;
D O I
10.1161/01.HYP.21.1.65
中图分类号
R6 [外科学];
学科分类号
1002 [临床医学]; 100210 [外科学];
摘要
We tested Portapres, an innovative portable, battery-operated device for the continuous, noninvasive, 24-hour ambulatory measurement of blood pressure in the finger. Portapres is based on Finapres, a stationary device for the measurement of finger arterial pressure. Systems were added to record signals on tape, to alternate measurements between fingers automatically each 30 minutes, and to correct for the hydrostatic height of the hand. We compared the pressure as measured by Portapres with contralateral intrabrachial pressure measured with an Oxford device. Results were obtained in eight volunteers and 16 hypertensive patients. Time lost due to artifact was about 10% for each device. In two patients a full 24-hour Oxford profile was not obtained. In the remaining 22 subjects finger systolic, diastolic, and mean pressures differed +1 (SD 9), -8 (6), and -10 (6) mm Hg, respectively, from intrabrachial pressure. These diastolic and mean pressure underestimations are similar to what was found earlier for Finapres, are typical for the technique, and are systematic. Avoiding brisk hand movements resulted in fewer waveform artifacts. The hand had to be kept covered to continue recording at low outside temperatures. Sleep was not disturbed by Portapres, and arterial pressure showed a marked fall during siesta and nighttime. There were no major limitations in behavior, and no discomfort that originated from continuous monitoring was reported. Measurements continued normally during physical exercise. Portapres provides for the first time continuous 24-hour, noninvasive ambulatory blood pressure waveform monitoring and offers real and obvious advantages over current noninvasive and invasive devices.
引用
收藏
页码:65 / 73
页数:9
相关论文
共 28 条
[1]
DIRECT BLOOD-PRESSURE MEASUREMENT - DYNAMIC-RESPONSE REQUIREMENTS [J].
GARDNER, RM .
ANESTHESIOLOGY, 1981, 54 (03) :227-236
[2]
COMPARISON OF FINAPRES NONINVASIVE BEAT-TO-BEAT FINGER BLOOD-PRESSURE WITH INTRABRACHIAL ARTERY PRESSURE DURING AND AFTER BICYCLE ERGOMETRY [J].
IDEMA, RN ;
VANDENMEIRACKER, AH ;
IMHOLZ, BPM ;
TVELD, AJMI ;
SETTELS, JJ ;
VANECK, HJR ;
SCHALEKAMP, MADH .
JOURNAL OF HYPERTENSION, 1989, 7 :S58-S59
[3]
Imholz B P, 1991, Clin Auton Res, V1, P43, DOI 10.1007/BF01826057
[4]
CONTINUOUS NON-INVASIVE BLOOD-PRESSURE MONITORING - RELIABILITY OF FINAPRES DEVICE DURING THE VALSALVA MANEUVER [J].
IMHOLZ, BPM ;
VANMONTFRANS, GA ;
SETTELS, JJ ;
VANDERHOEVEN, GMA ;
KAREMAKER, JM ;
WIELING, W .
CARDIOVASCULAR RESEARCH, 1988, 22 (06) :390-397
[5]
NONINVASIVE CONTINUOUS FINGER BLOOD-PRESSURE MEASUREMENT DURING ORTHOSTATIC STRESS COMPARED TO INTRAARTERIAL PRESSURE [J].
IMHOLZ, BPM ;
SETTELS, JJ ;
VANDERMEIRACKER, AH ;
WESSELING, KH ;
WIELING, W .
CARDIOVASCULAR RESEARCH, 1990, 24 (03) :214-221
[6]
MANCIA G, 1990, J HYPERTENS, V8, pS1
[7]
EXPERIENCE WITH 24-HOUR AMBULATORY BLOOD-PRESSURE MONITORING IN HYPERTENSION [J].
MANCIA, G ;
PARATI, G .
AMERICAN HEART JOURNAL, 1988, 116 (04) :1134-1140
[8]
THE SAFETY OF AMBULATORY INTRA-ARTERIAL PRESSURE MONITORING - A CLINICAL AUDIT OF 1000 STUDIES [J].
MANN, S ;
JONES, RI ;
MILLARCRAIG, MW ;
WOOD, C ;
GOULD, BA ;
RAFTERY, EB .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 1984, 5 (05) :585-597
[9]
NEW SYSTEM FOR RECORDING AMBULATORY BLOOD-PRESSURE IN MAN [J].
MILLARCRAIG, MW ;
HAWES, D ;
WHITTINGTON, J .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1978, 16 (06) :727-731
[10]
MILLARCRAIG MW, 1981, BIOTELEM PAT MON, V8, P56