A RAPID AND HIGHLY SENSITIVE METHOD FOR THE QUANTITATIVE-DETERMINATION OF DEXAMETHASONE IN PLASMA, SYNOVIAL-FLUID AND TISSUES BY COMBINED GAS-CHROMATOGRAPHY NEGATIVE-ION CHEMICAL IONIZATION MASS-SPECTROMETRY

被引:20
作者
GIRAULT, J
ISTIN, B
FOURTILLAN, JB
机构
[1] CEMAF, Poitiers, 86000
来源
BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY | 1990年 / 19卷 / 05期
关键词
D O I
10.1002/bms.1200190504
中图分类号
O433 [光谱学];
学科分类号
0703 [化学]; 070302 [分析化学];
摘要
A new, simple and highly sensitive assay is developed for the quantitative measurement of very low levels of dexamethasone in human plasma, synovial fluid and tissues following a topical administration of the drug. Dexamethasone and the internal standard, flumethasone, are measured by gas chromatography/negative ion chemical ionization mass spectrometry with methane as the reagent gas. After a three‐step extraction procedure, the two compounds of interest are converted to their trimethylsilyl ether derivatives using trimethylsilylimidazole and formamide as the base catalyst. Under soft derivatization conditions only one chromatographic peak corresponding to the trisubstituted derivative is observed. The mass spectrometer is focused to monitor abundant and stable characteristic high‐mass ions (m/z 446 and 464) which are generated in the ion source by an electron capture process. This assay requires only 1 ml of plasma or 0.5 ml of synovial fluid and the detection limit of the method is equal to 0.1 ng ml−1 with a relative standard deviation lower than 6%. Copyright © 1990 John Wiley & Sons, Ltd.
引用
收藏
页码:295 / 302
页数:8
相关论文
共 28 条
[1]
BAILLIE TA, 1972, ANAL CHEM, V4, P30
[2]
BEYER WF, 1982, US PHARMACOPEIAL CON, P2233
[3]
LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY OF DEXAMETHASONE AND BETAMETHASONE [J].
CAIRNS, T ;
SIEGMUND, EG ;
STAMP, JJ ;
SKELLY, JP .
BIOMEDICAL MASS SPECTROMETRY, 1983, 10 (03) :203-208
[4]
CHAMBAZ EM, 1973, ANAL CHEM, V45, P1090
[5]
DEPAOLIS AM, 1977, J ASSOC OFF ANA CHEM, V60, P210
[6]
DUGGAN DE, 1975, CLIN PHARMACOL THER, V18, P205
[7]
QUANTITATIVE MEASUREMENT OF CLONIDINE IN HUMAN-PLASMA BY COMBINED GAS-CHROMATOGRAPHY ELECTRON-CAPTURE NEGATIVE-ION CHEMICAL IONIZATION MASS-SPECTROMETRY [J].
GIRAULT, J ;
FOURTILLAN, JB .
BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1988, 17 (06) :443-448
[8]
HARE LE, 1975, CLIN PHARMACOL THER, V18, P330
[9]
HENION JD, 1985, J CHROMATOGR LIBR, V30, P273
[10]
ELECTRON-CAPTURE NEGATIVE CHEMICAL IONIZATION MASS-SPECTROMETRY OF CHEMICALLY OXIDIZED CORTICOSTEROIDS [J].
HER, GR ;
WATSON, JT .
BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1986, 13 (02) :57-63