COMPARISON OF FLUORESCENCE-BASED SEMIAUTOMATED GENOTYPING OF MULTIPLE MICROSATELLITE LOCI WITH AUTORADIOGRAPHIC TECHNIQUES

被引:91
作者
SCHWENGEL, DA
JEDLICKA, AE
NANTHAKUMAR, EJ
WEBER, JL
LEVITT, RC
机构
[1] JOHNS HOPKINS MED INST,DEPT ANESTHESIOL & CRIT CARE MED,BALTIMORE,MD 21287
[2] JOHNS HOPKINS MED INST,DEPT MED,BALTIMORE,MD 21287
[3] MARSHFIELD MED RES FDN,MARSHFIELD,WI 54449
关键词
D O I
10.1006/geno.1994.1344
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The practical application of highly efficient fluorescence-based methods for the semi-automated genotyping of polymerase chain reaction-based microsatellite markers will depend on the development of robust protocols that provide accurate and reproducible data. In the present report we compare the accuracy of a fluorescence-based protocol with a benchmark radiolabeling method that depends on a known sequence ladder or amplified DNA from reference individuals for sizing by autoradiography. Three microsatellite markers, IGF1 (mfd 1), D4S174 (mfd 59), and D5S211 (mfd 154), with products overlapping in size were each labeled with a different fluorophore and run simultaneously with an internal size standard in a single electrophoretic lane. The size of each allele was compared for these markers by using both techniques for five larger CEPH families (884, 1331, 1332, 1333, and 1362). Of 462 possible alleles, four discrepancies (0.8%) were identified when the two approaches were compared. We conclude that the fluorescence-based protocol is at least as accurate as the standard radiolabeling technique since none of the sizing errors arose as a result of the fluorescence-based technique. We describe the adaptation of this fluorescence based protocol to the simultaneous analysis of up to 24 microsatellite loci per electrophoretic lane. These highly accurate and efficient semi-automated techniques will be useful in high-resolution genomic analyses. (C) 1994 Academic Press, lnc.
引用
收藏
页码:46 / 54
页数:9
相关论文
共 18 条
[1]   SURVEY OF HUMAN AND RAT MICROSATELLITES [J].
BECKMANN, JS ;
WEBER, JL .
GENOMICS, 1992, 12 (04) :627-631
[2]  
BOTSTEIN D, 1980, AM J HUM GENET, V32, P314
[3]   A HIGH-RESOLUTION, FLUORESCENCE-BASED, SEMIAUTOMATED METHOD FOR DNA FINGERPRINTING [J].
CARRANO, AV ;
LAMERDIN, J ;
ASHWORTH, LK ;
WATKINS, B ;
BRANSCOMB, E ;
SLEZAK, T ;
RAFF, M ;
DEJONG, PJ ;
KEITH, D ;
MCBRIDE, L ;
MEISTER, S ;
KRONICK, M .
GENOMICS, 1989, 4 (02) :129-136
[4]  
CONNELL C, 1987, BIOTECHNIQUES, V5, P342
[5]  
DIEHL SR, 1990, AM J HUM GENET, V47, pA177
[6]   A GENETIC-LINKAGE MAP OF THE HUMAN GENOME [J].
DONISKELLER, H ;
GREEN, P ;
HELMS, C ;
CARTINHOUR, S ;
WEIFFENBACH, B ;
STEPHENS, K ;
KEITH, TP ;
BOWDEN, DW ;
SMITH, DR ;
LANDER, ES ;
BOTSTEIN, D ;
AKOTS, G ;
REDIKER, KS ;
GRAVIUS, T ;
BROWN, VA ;
RISING, MB ;
PARKER, C ;
POWERS, JA ;
WATT, DE ;
KAUFFMAN, ER ;
BRICKER, A ;
PHIPPS, P ;
MULLERKAHLE, H ;
FULTON, TR ;
NG, S ;
SCHUMM, JW ;
BRAMAN, JC ;
KNOWLTON, RG ;
BARKER, DF ;
CROOKS, SM ;
LINCOLN, SE ;
DALY, MJ ;
ABRAHAMSON, J .
CELL, 1987, 51 (02) :319-337
[7]  
EDWARDS A, 1991, AM J HUM GENET, V49, P746
[8]  
H/CEPH Collaborative Mapping Group, 1992, SCIENCE, V258, P67
[9]  
LANDER ES, 1991, AM J HUM GENET, V48, P819
[10]   QUANTITATIVE FILM DETECTION OF H-3 AND C-14 IN POLYACRYLAMIDE GELS BY FLUOROGRAPHY [J].
LASKEY, RA ;
MILLS, AD .
EUROPEAN JOURNAL OF BIOCHEMISTRY, 1975, 56 (02) :335-341