INTRATHECAL ADMINISTRATION OF HYPERBARIC MORPHINE FOR THE RELIEF OF PAIN IN LABOR

被引:69
作者
ABBOUD, TK
SHNIDER, SM
DAILEY, PA
RAYA, JA
SARKIS, F
GROBLER, NM
SADRI, S
KHOO, SS
DESOUSA, B
BAYSINGER, CL
MILLER, F
机构
[1] UNIV SO CALIF, LOS ANGELES CTY MED CTR, DEPT ANESTHESIA, 1200 N STATE ST, BOX 12, LOS ANGELES, CA 90033 USA
[2] UNIV CALIF SAN FRANCISCO, DEPT ANESTHESIA, SAN FRANCISCO, CA 94143 USA
[3] UNIV SO CALIF, LOS ANGELES CTY MED CTR, DEPT OBSTET & GYNECOL, LOS ANGELES, CA 90033 USA
关键词
D O I
10.1093/bja/56.12.1351
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Healthy women (30) in active labor received an intrathecal injection of morphine 0.5 mg (n = 12) or 1 mg (n = 18) in 7.5% dextrose. Both doses provided excellent analgesia for labor, 93% of patients obtaining at least 50% pain relief. Analgesia began 15-60 min after injection and did not decrease until 6-8 h after injection. Analgesia was satisfactory until distension of the perineum, either by forceps or the infant''s head. The intrathecal injection of morphine did not adversely affect the condition of the infant. Eighty percent of patients developed pruritus; 53%, nausea or vomiting, or both; 43%, urinary retention; and 43%, drowsiness. These side effects were decreased by naloxone, which did not affect the degree of analgesia. There was no significant depression of ventilation in any patients. Evidently morphine 0.5 or 1 mg, administered intrathecally, effectively decreases the pain of labor, and i.v. administration of naloxone can alleviate the common side effects.
引用
收藏
页码:1351 / 1360
页数:10
相关论文
共 15 条
  • [1] A NEW NEUROLOGIC AND ADAPTIVE CAPACITY SCORING SYSTEM FOR EVALUATING OBSTETRIC MEDICATIONS IN FULL-TERM NEWBORNS
    AMIELTISON, C
    BARRIER, G
    SHNIDER, SM
    LEVINSON, G
    HUGHES, SC
    STEFANI, SJ
    [J]. ANESTHESIOLOGY, 1982, 56 (05) : 340 - 350
  • [2] INTRATHECAL INJECTION OF MORPHINE FOR OBSTETRIC ANALGESIA
    BARAKA, A
    NOUEIHID, R
    HAJJ, S
    [J]. ANESTHESIOLOGY, 1981, 54 (02) : 136 - 140
  • [3] BROMAGE PR, 1982, ANESTH ANALG, V61, P490
  • [4] BROOKSHIRE GL, 1983, ANESTHESIOLOGY, V59, pA417
  • [5] INTRATHECAL MORPHINE IN OBSTETRICS
    CRAWFORD, JS
    [J]. ANESTHESIOLOGY, 1981, 55 (04) : 487 - 487
  • [6] ESTIMATION OF ARTERIAL PO2, PCO2, PH, AND LACTATE FROM ARTERIALIZED VENOUS-BLOOD
    FORSTER, HV
    DEMPSEY, JA
    DOPICO, GA
    VIDRUK, E
    THOMSON, J
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1972, 32 (01) : 134 - &
  • [7] GLYNN CJ, 1979, LANCET, V2, P356
  • [8] HEFFRON CH, 1978, PERINATAL CARE, V2, P14
  • [9] HUGHES SC, 1984, ANESTH ANALG, V63, P319
  • [10] FAILURE OF EPIDURAL MORPHINE TO RELIEVE PAIN IN LABOR
    HUSEMEYER, RP
    OCONNOR, MC
    DAVENPORT, HT
    [J]. ANAESTHESIA, 1980, 35 (02) : 161 - 163