We examined samples of tissue and components that had been removed during twenty revisions of total hip arthroplasties in which a titanium-alloy femoral component had been used. Minute amounts of metallic debris were detected in the tissues from two patients. The amounts of polyethylene and methylmethacrylate debris and the histological reactions in the tissues corresponded closely with those reported in earlier studies of total hip prostheses made of stainless steel or cobalt-chromium alloy.
引用
收藏
页码:512 / 517
页数:6
相关论文
共 24 条
[1]   METALLIC WEAR IN FAILED TITANIUM-ALLOY TOTAL HIP REPLACEMENTS - A HISTOLOGICAL AND QUANTITATIVE-ANALYSIS [J].
AGINS, HJ ;
ALCOCK, NW ;
BANSAL, M ;
SALVATI, EA ;
WILSON, PD ;
PELLICCI, PM ;
BULLOUGH, PG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (03) :347-356
[2]   METALLOSIS ASSOCIATED WITH A STABLE TITANIUM-ALLOY FEMORAL COMPONENT IN TOTAL HIP-REPLACEMENT - A CASE-REPORT [J].
BLACK, J ;
SHERK, H ;
BONINI, J ;
ROSTOKER, WR ;
SCHAJOWICZ, F ;
GALANTE, JO .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (01) :126-130
[3]   WEAR-ACCELERATED CORROSION OF TI-6AL-4V AND NITROGEN-ION-IMPLANTED TI-6AL-4V - MECHANISMS AND INFLUENCE OF FIXED-STRESS MAGNITUDE [J].
BUCHANAN, RA ;
RIGNEY, ED ;
WILLIAMS, JM .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1987, 21 (03) :367-377
[4]   ION-IMPLANTATION OF SURGICAL TI-6AL-4V FOR IMPROVED RESISTANCE TO WEAR-ACCELERATED CORROSION [J].
BUCHANAN, RA ;
RIGNEY, ED ;
WILLIAMS, JM .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1987, 21 (03) :355-366
[5]   EXCESSIVE METAL RELEASE DUE TO LOOSENING AND FRETTING OF SINTERED PARTICLES ON POROUS-COATED HIP PROSTHESES - REPORT OF 2 CASES [J].
BUCHERT, PK ;
VAUGHN, BK ;
MALLORY, TH ;
ENGH, CA ;
BOBYN, JD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (04) :606-609
[6]  
CLARKE IC, 1976, CLIN ORTHOP RELAT R, P126
[7]  
CLARKE IC, 1983, ASTM STP, V796, P136
[8]  
GRIFFITH MJ, 1978, CLIN ORTHOP RELAT R, V137, P37
[9]   FRICTION AND WEAR PROPERTIES OF POLYMER, METAL, AND CERAMIC PROSTHETIC JOINT MATERIALS EVALUATED ON A MULTICHANNEL SCREENING DEVICE [J].
MCKELLOP, H ;
CLARKE, I ;
MARKOLF, K ;
AMSTUTZ, H .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1981, 15 (05) :619-653
[10]  
MCKELLOP H, 1980, T ORTHOP RES SOC, V5, P96