QUANTIFICATION OF ULTRASOUND EMBOLI SIGNALS IN PATIENTS WITH CARDIAC AND CAROTID DISEASE

被引:77
作者
GROSSET, DG [1 ]
GEORGIADIS, D [1 ]
KELMAN, AW [1 ]
LEES, KR [1 ]
机构
[1] WESTERN INFIRM & ASSOCIATED HOSP,ACUTE STROKE UNIT,GLASGOW,SCOTLAND
关键词
CEREBROVASCULAR DISORDERS; EMBOLISM; ULTRASONICS;
D O I
10.1161/01.STR.24.12.1922
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose: The use of Doppler ultrasound to detect arterial emboli has major implications for the classification and treatment of stroke. Experimental studies indicate that embolic materials produce different ultrasound signals, depending on their acoustic properties. To examine the possibility of characterizing emboli of different sources in the clinical setting, we compared the emboli signals of patients with cardiac embolic sources with those of patients with signals of carotid embolic sources. Methods: Transcranial Doppler monitoring (30 minutes per patient) of the middle cerebral arteries was performed in 80 patients with prosthetic cardiac valves and 20 patients with internal carotid artery stenosis. The signal power of emboli was calculated in relation to the background Doppler signal. Results: In patients who were embolizing from prosthetic heart valves, the frequency of embolus signals was greater than in patients with carotid stenosis who were embolizing (mean+/-SEM: 58.2+/-11 versus 8.2+/-3 signals per hour, P<.0001, two-sample t test), and total signal power and duration also were higher (power, 2231+/-63 versus 455+/-109 power units; duration, 55.9+/-0.8 versus 29.9+/-1.4 milliseconds; both P<.001). The majority of emboli signals were seen during cardiac systole, especially in patients with carotid stenosis (89% in the first half of the cardiac cycle versus 72% in prosthetic valve patients). In 19 patients with prosthetic valves, embolus signals were also recorded from the anterior cerebral artery; the signal count was not significantly different from the middle cerebral artery (43.2+/-12.5 versus 64.3+/-16 per hour), but anterior cerebral artery signals were of higher power (3306+/-148 versus 2441+/-109 power units, P<.001). Conclusions: There is promise of being able to distinguish emboli on the basis of power measurements. Emboli of different sources (eg, carotid and cardiac) appear to have different ultrasonic characteristics, which are likely to be based on composition and size.
引用
收藏
页码:1922 / 1924
页数:3
相关论文
共 14 条
  • [1] BERGER M, 1990, J CARDIOVASC TECHNOL, V9, P282
  • [2] DETECTION OF MIDDLE CEREBRAL EMBOLI DURING CORONARY-ARTERY BYPASS-SURGERY USING TRANSCRANIAL DOPPLER SONOGRAPHY
    HARRISON, MJG
    PUGSLEY, W
    NEWMAN, S
    PASCHALIS, C
    KLINGER, L
    TREASURE, T
    ASPEY, B
    [J]. STROKE, 1990, 21 (10) : 1512 - 1512
  • [3] MARKUS HS, 1993, STROKE, V24, P1
  • [4] RESPONSE OF MIDDLE CEREBRAL-ARTERY VOLUME FLOW TO ORTHOSTASIS
    MULLER, HR
    CASTY, M
    MOLL, R
    ZEHNDER, R
    [J]. CEREBROVASCULAR DISEASES, 1991, 1 (02) : 82 - 89
  • [5] THE DETECTION OF MICROEMBOLI IN THE MIDDLE CEREBRAL-ARTERY DURING CARDIOPULMONARY BYPASS - A TRANSCRANIAL DOPPLER ULTRASOUND INVESTIGATION USING MEMBRANE AND BUBBLE OXYGENATORS
    PADAYACHEE, TS
    PARSONS, S
    THEOBOLD, R
    LINLEY, J
    GOSLING, RG
    DEVERALL, PB
    [J]. ANNALS OF THORACIC SURGERY, 1987, 44 (03) : 298 - 302
  • [6] MICROEMBOLI AND CEREBRAL IMPAIRMENT DURING CARDIAC-SURGERY
    PUGSLEY, W
    KLINGER, L
    PASCHALIS, C
    ASPEY, B
    NEWMAN, S
    HARRISON, M
    TREASURE, T
    [J]. VASCULAR SURGERY, 1990, 24 (01): : 34 - 43
  • [7] DETECTION OF ARTERIAL EMBOLI USING DOPPLER ULTRASOUND IN RABBITS
    RUSSELL, D
    MADDEN, KP
    CLARK, WM
    SANDSET, PM
    ZIVIN, JA
    [J]. STROKE, 1991, 22 (02) : 253 - 258
  • [8] DETECTION OF INTRACRANIAL EMBOLI IN PATIENTS WITH SYMPTOMATIC EXTRACRANIAL CAROTID-ARTERY DISEASE
    SIEBLER, M
    SITZER, M
    STEINMETZ, H
    [J]. STROKE, 1992, 23 (11) : 1652 - 1654
  • [9] Spencer M P, 1969, Ann Thorac Surg, V8, P489
  • [10] SPENCER MP, 1969, JOM-J OCCUP MED, V11, P238