SELECTIVITY COEFFICIENTS FOR AMPEROMETRIC SENSORS

被引:99
作者
WANG, J
机构
[1] Department of Chemistry and Biochemistry, New Mexico State University, Las Cruces
关键词
D O I
10.1016/0039-9140(94)E0079-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Selectivity coefficients (k(ij)amp) are introduced as well-defined measures of the selectivity of amperometric sensors. For any amperometric device the total current response in the presence of interfering species (j) can be described by the general equation; i(t) = K(C(i) + SIGMAk(ij)ampC(j)), where i is the target analyte. Equations are derived for k(ij)amp under different conditions common in amperometric sensing. Factors influencing the selectivity coefficients of amperometric probes, including the recognition and transduction mechanisms, the controlled-potential operating technique, and the transducer geometry are discussed. The selectivity coefficient strategy is illustrated experimentally with two widely used applications of amperometric devices, the anodic monitoring of dopamine at Nafion-coated electrodes and the biosensing of glucose at glucose-oxidase enzyme probes. It is anticipated that the selectivity coefficient strategy will become widespread in amperometric devices, and for chemical sensors in general, and will not be limited only to potentiometric probes.
引用
收藏
页码:857 / 863
页数:7
相关论文
共 21 条
[1]   AN AMPEROMETRIC GLUCOSE ELECTRODE BASED ON CARBON PASTE, CHEMICALLY MODIFIED WITH GLUCOSE-DEHYDROGENASE, NICOTINAMIDE ADENINE-DINUCLEOTIDE, AND A PHENOXAZINE MEDIATOR, COATED WITH A POLY(ESTER SULFONIC-ACID) CATION EXCHANGER [J].
BREMLE, G ;
PERSSON, B ;
GORTON, L .
ELECTROANALYSIS, 1991, 3 (02) :77-86
[2]   POTENTIOMETRIC SELECTIVITY COEFFICIENTS OF LIQUID ION-EXCHANGE MEMBRANES FOR UNIVALENT AND DIVALENT IONS [J].
BUCK, RP ;
STOVER, FS .
ANALYTICA CHIMICA ACTA, 1978, 101 (02) :231-238
[3]   NAFION-COATED CARBON-FIBER ELECTRODES FOR NEUROCHEMICAL STUDIES IN BRAIN-TISSUE [J].
CAPELLA, P ;
GHASEMZADEH, B ;
MITCHELL, K ;
ADAMS, RN .
ELECTROANALYSIS, 1990, 2 (03) :175-182
[4]  
CZABAN JD, 1985, ANAL CHEM, V57, pA345
[5]   EVALUATION OF NAFION AS MEDIA FOR GLUCOSE-OXIDASE IMMOBILIZATION FOR THE DEVELOPMENT OF AN AMPEROMETRIC GLUCOSE BIOSENSOR [J].
FORTIER, G ;
VAILLANCOURT, M ;
BELANGER, D .
ELECTROANALYSIS, 1992, 4 (03) :275-283
[6]   ELECTROCHEMICAL BIOSENSORS [J].
FREW, JE ;
HILL, HAO .
ANALYTICAL CHEMISTRY, 1987, 59 (15) :A933-&
[7]   MEMBRANE-COVERED, ROTATED DISK ELECTRODE [J].
GOUGH, DA ;
LEYPOLDT, JK .
ANALYTICAL CHEMISTRY, 1979, 51 (03) :439-444
[8]   CHEMICALLY MODIFIED CARBON PASTE ELECTRODES IN VOLTAMMETRIC ANALYSIS [J].
KALCHER, K .
ELECTROANALYSIS, 1990, 2 (06) :419-433
[9]   GLUCOSE FAST-RESPONSE AMPEROMETRIC SENSOR BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN AN ELECTROPOLYMERIZED POLY(ORTHO-PHENYLENEDIAMINE) FILM [J].
MALITESTA, C ;
PALMISANO, F ;
TORSI, L ;
ZAMBONIN, PG .
ANALYTICAL CHEMISTRY, 1990, 62 (24) :2735-2740
[10]  
NIKOLSKY BP, 1967, GLASS ELECTRODES HYD