EVALUATION AND VALIDATION OF INSTRUMENTAL PROCEDURES FOR THE DETERMINATION OF NICKEL AND VANADIUM IN FUEL OILS

被引:45
作者
BETTINELLI, M [1 ]
TITTARELLI, P [1 ]
机构
[1] STN SPERIMENTALE COMBUSTIBILI,I-20097 SAN DONATO MILANE,ITALY
关键词
NICKEL; VANADIUM; FUEL OIL; FLAME ATOMIC ABSORPTION SPECTROMETRY; VALIDATION;
D O I
10.1039/ja9940900805
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
A direct method for the determination of Ni and V in fuel oils by flame atomic absorption spectrometry has been developed which is sufficiently rapid, accurate and precise for monitoring batches of fuel oil. Fifty-four European laboratories participated in the round-robin test (RRT), which was carried out on six fuel oil samples in order to evaluate the precision of the method. Various procedures and instrumental techniques such as electrothermal atomic absorption spectrometry, inductively coupled plasma atomic emission spectrometry, X-ray fluorescence, inductively coupled plasma mass spectrometry and neutron activation analysis were employed to control the accuracy of the results. The participating laboratories provided 1879 results for Ni and 1945 results for V. The precision of the flame direct method (FDM) was calculated according to the ISO 5725 method. The repeatability and reproducibility data for the FDM showed definite improvements on comparison with the precision data given by the Institute of Petroleum (IP) 288 method. The limit of determination (six times the interlaboratory standard deviation of the FO01NV sample) was 5.6 mug g-1 for Ni and 4.2 mug g-1 for V. In the concentration range investigated (1-70 mug g-1 of Ni and 2-180 mug g-1 of V) the repeatability (r) and reproducibility (R) showed a linear relationship with both element contents. The r values were 3.4 mug g-1 for an Ni content of 30 g g-1 and 3.8 mug g-1 for a V content of 50 mug g-1, while the R values for the same element contents, were, respectively, 8.1 mug g-1 for Ni and 11.1 mug g-1 for V. Evaluation of the accuracy of the method was also performed using standard reference materials. The instrumental techniques showed the results to be in excellent agreement. The control of accuracy and the comparison of results obtained by the independent techniques allowed validation of the proposed method. Therefore, it was possible to advance consensus values for the Ni and V content in the six fuel oil samples examined in the RRT.
引用
收藏
页码:805 / 812
页数:8
相关论文
共 27 条
[1]
[Anonymous], 1991, 1991 ANN BOOK ASTM S, V5.01, P580
[2]
Properties of sufficiency and statistical tests [J].
Bartlett, MS .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1937, 160 (A901) :0268-0282
[3]
CONCENTRATION-DATA OF ELEMENTS IN LIQUID FUEL OILS AS OBTAINED BY NEUTRON-ACTIVATION ANALYSIS [J].
BLOCK, C ;
DAMS, R .
JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1978, 46 (01) :137-144
[4]
BROWN RJ, 1984, SPECTROCHIM ACTA B, V38, P283
[5]
DIRECT DETERMINATION OF NICKEL IN GAS OIL BY ATOMIC-ABSORPTION SPECTROMETRY WITH ELECTROTHERMAL ATOMIZATION [J].
BRUHN, C ;
CABALIN, V .
ANALYTICA CHIMICA ACTA, 1983, 147 (MAR) :193-203
[6]
DELAGUARDIA M, 1983, ATOM SPECTROSC, V4, P208
[7]
DETERMINATION OF SULFUR, NICKEL AND VANADIUM IN FUEL AND RESIDUAL OILS BY X-RAY-FLUORESCENCE SPECTROMETRY [J].
DENOYER, ER ;
SIEGEL, LA .
ANALYTICA CHIMICA ACTA, 1987, 192 (02) :361-366
[8]
DETERMINATION OF NICKEL, VANADIUM, AND SULFUR IN CRUDES AND HEAVY CRUDE FRACTIONS BY INDUCTIVELY COUPLED ARGON PLASMA ATOMIC EMISSION-SPECTROMETRY AND FLAME ATOMIC-ABSORPTION SPECTROMETRY [J].
FABEC, JL ;
RUSCHAK, ML .
ANALYTICAL CHEMISTRY, 1985, 57 (09) :1853-1863
[9]
EVALUATION OF RESIDUAL FUEL-OIL STANDARD REFERENCE MATERIALS AS TRACE-ELEMENT STANDARDS [J].
FILBY, RH ;
VANBERKEL, GJ ;
BRAGG, AE ;
JOUBERT, A ;
ROBISON, WE ;
GRIMM, CA .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1985, 91 (02) :361-368
[10]
HAUSLER DW, 1991, SPECTROCHIM ACTA REV, V14, P124