A VARIABLE DISPERSION ARRAY DETECTOR FOR A TANDEM MASS-SPECTROMETER

被引:11
作者
HILL, JA [1 ]
BILLER, JE [1 ]
BIEMANN, K [1 ]
机构
[1] MIT,DEPT CHEM,CAMBRIDGE,MA 02139
来源
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES | 1991年 / 111卷
关键词
D O I
10.1016/0168-1176(91)85045-N
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Incorporation of a pair of quadrupole lenses and one octapole lens after the second magnetic field of a JEOL HX110/HX110 tandem mass spectrometer permits varying the dispersion and therefore the mass range that can be focused on a 2 in array detector. This range can be adjusted from a value of 1:1.04 to 1:1.3 for the ratio of low m/z to high m/z falling at the extremes of the detector. The ratio is governed by the d.c. potentials on the lenses which also changes the angle of the resulting focal plane and thus requires that the position of the array detector must be changed accordingly. In the system described, all these variables are under computer control and can be adjusted within 1 s, thus allowing for a change even during the recording of a spectrum if one wishes to minimize the number of segments to be recorded to cover the entire spectrum while still maintaining unit mass resolution. The variable range array detector is useful for the recording of normal mass spectra as well as those generated upon collision induced decomposition (CID) of precursor ions. In the latter case, the refocusing of the ion beams through the quadrupole lens system is more complex but the software controls the lens potentials accordingly. The system has been used to record the normal or CID spectra of peptides, either from a static sample or eluting from a high performance liquid chromatograph.
引用
收藏
页码:1 / 25
页数:25
相关论文
共 13 条
[1]   CONTRIBUTIONS OF MASS-SPECTROMETRY TO PEPTIDE AND PROTEIN-STRUCTURE [J].
BIEMANN, K .
BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1988, 16 (1-12) :99-111
[2]   EFFICIENT INTRODUCTION OF HPLC FRACTIONS INTO A HIGH-PERFORMANCE TANDEM MASS-SPECTROMETER [J].
CAPPIELLO, A ;
PALMA, P ;
PAPAYANNOPOULOS, IA ;
BIEMANN, K .
CHROMATOGRAPHIA, 1990, 30 (9-10) :477-483
[3]   CHARACTERISTICS OF A MULTICHANNEL ELECTROOPTICAL DETECTION SYSTEM AND ITS APPLICATION TO THE ANALYSIS OF LARGE MOLECULES BY FAST-ATOM-BOMBARDMENT MASS-SPECTROMETRY [J].
COTTRELL, JS ;
EVANS, S .
ANALYTICAL CHEMISTRY, 1987, 59 (15) :1990-1995
[4]   TANDEM MASS-SPECTROMETRY - MULTISECTOR MAGNETIC INSTRUMENTS [J].
GROSS, ML .
METHODS IN ENZYMOLOGY, 1990, 193 :131-153
[5]   USE OF A MICROCHANNEL ARRAY DETECTOR IN A 4-SECTOR TANDEM MASS-SPECTROMETER [J].
HILL, JA ;
MARTIN, SA ;
BILLER, JE ;
BIEMANN, K .
BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1988, 17 (02) :147-151
[6]   DESIGN CONSIDERATIONS, CALIBRATION AND APPLICATIONS OF AN ARRAY DETECTOR FOR A 4-SECTOR TANDEM MASS-SPECTROMETER [J].
HILL, JA ;
BILLER, JE ;
MARTIN, SA ;
BIEMANN, K ;
YOSHIDOME, K ;
SATO, K .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1989, 92 :211-230
[7]  
HILL JA, 1991, 38TH P ASMS C MASS S, P495
[8]  
ISHIHARA M, 1989, RAPID COMMUN MASS SP, V3, P420
[9]   A COMPARISON OF KEV ATOM BOMBARDMENT MASS-SPECTRA OF PEPTIDES OBTAINED WITH A 2-SECTOR MASS-SPECTROMETER WITH THOSE FROM A 4-SECTOR TANDEM MASS-SPECTROMETER [J].
MARTIN, SA ;
BIEMANN, K .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1987, 78 :213-228
[10]   ENHANCED MASS RESOLUTION WITHOUT DECREASE OF BEAM INTENSITY IN A 4 SECTOR MASS-SPECTROMETER [J].
MATSUO, T ;
ISHIHARA, M ;
MARTIN, SA ;
BIEMANN, K .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1988, 86 :83-94