RETROSPECTIVE REGISTRATION OF PET AND MR BRAIN IMAGES - AN ALGORITHM AND ITS STEREOTAXIC VALIDATION

被引:21
作者
GE, YR
FITZPATRICK, JM
VOTAW, JR
GADAMSETTY, S
MACIUNAS, RJ
KESSLER, RM
MARGOLIN, RA
机构
[1] VANDERBILT UNIV, DEPT COMP SCI, NASHVILLE, TN 37235 USA
[2] VANDERBILT UNIV, DEPT PSYCHIAT, NASHVILLE, TN USA
[3] VANDERBILT UNIV, DEPT RADIOL & RADIOL SCI, NASHVILLE, TN USA
[4] VANDERBILT UNIV, DEPT NEUROSURG, NASHVILLE, TN USA
关键词
STEREOTAXY; IMAGE REGISTRATION; EMISSION COMPUTED TOMOGRAPHY; MAGNETIC RESONANCE IMAGING;
D O I
10.1097/00004728-199409000-00021
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: We present a validation study of an algorithm for retrospective registration of PET and MR brain images. Materials and Methods: This algorithm involves two steps. In the first step, the two volumes are reformatted by aligning their interhemispheric fissure planes (midsagittal plane). In the second step, the corresponding planes parallel to the midsagittal plane are further aligned in the reformatted volumes to produce a 3D rigid body registration of the two original volumes. It is an efficient algorithm because both steps are performed in 2D spaces, and in each step only a small number of landmarks are required. A user-friendly system has been implemented to facilitate easy and fast processing of registration and reformatting of image volumes. The accuracy of this algorithm is validated using clinical scans of neurosurgical patients with a stereotaxic frame attached to their skull. The frame-based stereotaxic system provides an effective method for transforming image coordinates from different image volumes into a common coordinate system. This common coordinate system is used for assessing the spatial correspondence of each pixel in the registered image volumes. Validation using the stereotaxic image volumes enables objective estimation of retrospective registration accuracy. Results: Analysis of 11 MR/PET image pairs indicates that our registration method not only is efficient but also provides adequate accuracy for most clinical evaluation of PET studies. Conclusion: We have implemented and validated an efficient algorithm for retrospective registration of PET and MR brain images.
引用
收藏
页码:800 / 810
页数:11
相关论文
共 25 条
[1]  
Brown RA, 1986, US patent, Patent No. 4608977
[2]   HOUGH TRANSFORM DETECTION OF THE LONGITUDINAL FISSURE IN TOMOGRAPHIC HEAD IMAGES [J].
BRUMMER, ME .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (01) :74-87
[3]   A TECHNIQUE FOR ACCURATE MAGNETIC-RESONANCE-IMAGING IN THE PRESENCE OF FIELD INHOMOGENEITIES [J].
CHANG, H ;
FITZPATRICK, JM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (03) :319-329
[4]  
CHU SCK, 1990, MAGN RESON MED, V13, P239, DOI 10.1002/mrm.1910130207
[5]  
CORREIA JA, 1990, J NUCL MED, V31, P1227
[6]  
DONG S, 1992, JUN P COMP BAS MED S
[7]   MRI-PET CORRELATION IN 3 DIMENSIONS USING A VOLUME-OF-INTEREST (VOI) ATLAS [J].
EVANS, AC ;
MARRETT, S ;
TORRESCORZO, J ;
KU, S ;
COLLINS, L .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1991, 11 (02) :A69-A78
[8]   ORIENTATION OF 3-D STRUCTURES IN MEDICAL IMAGES [J].
FABER, TL ;
STOKELY, EM .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1988, 10 (05) :626-633
[9]   HEPARAN-SULFATE PROTEOGLYCANS [J].
GALLAGHER, JT ;
TURNBULL, JE ;
LYON, M .
BIOCHEMICAL SOCIETY TRANSACTIONS, 1990, 18 (02) :207-209
[10]  
GE Y, 1992, P SPIE MED IMAG, V6, P397