PREDICTORS OF THROMBOTIC COMPLICATIONS AFTER PLACEMENT OF THE FLEXIBLE COIL STENT

被引:77
作者
AGRAWAL, SK
HO, DSW
LIU, MW
IYER, S
HEARN, JA
CANNON, AD
MACANDER, PJ
DEAN, LS
BAXLEY, WA
ROUBIN, GS
机构
[1] Division of Cardiovascular Diseases, Department of Medicine, University of Alabama at Birmingham, Birmingham, AL
关键词
D O I
10.1016/0002-9149(94)90186-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The balloon-expandable, stainless steel, flexible coil stent is a useful device for managing acute or threatened closure after percutaneous transluminal coronary angioplasty.1-5 Use of the device is associated with thrombosis of the stented vessel in a small but important group of patients.3,6-10 The clinical, angiographic, and procedural factors associated with stent thrombosis with this device are still unknown. The objective of this study was to define predictors of stent thrombosis occurring within the ftrst month after stenting with this device. © 1994.
引用
收藏
页码:1216 / 1219
页数:4
相关论文
共 17 条
[1]  
CANNON AD, 1991, J INVASIVE CARDIOL, V3, P241
[2]   ANGIOGRAPHIC AND CLINICAL OUTCOME OF INTRACORONARY STENTING - IMMEDIATE AND LONG-TERM RESULTS FROM A LARGE SINGLE-CENTER EXPERIENCE [J].
CARROZZA, JP ;
KUNTZ, RE ;
LEVINE, MJ ;
POMERANTZ, RM ;
FISHMAN, RF ;
MANSOUR, M ;
GIBSON, CM ;
SENERCHIA, CC ;
DIVER, DJ ;
SAFIAN, RD ;
BAIM, DS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (02) :328-337
[3]   EMERGENCY STENTING FOR REFRACTORY ACUTE CORONARY-ARTERY OCCLUSION DURING CORONARY ANGIOPLASTY [J].
DEFEYTER, PJ ;
DESCHEERDER, I ;
VANDENBRAND, M ;
LAARMAN, GJ ;
SURYAPRANATA, H ;
SERRUYS, PW .
AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (15) :1147-1150
[4]   ANGIOGRAPHIC AND CLINICAL PREDICTORS OF ACUTE CLOSURE AFTER NATIVE VESSEL CORONARY ANGIOPLASTY [J].
ELLIS, SG ;
ROUBIN, GS ;
KING, SB ;
DOUGLAS, JS ;
WEINTRAUB, WS ;
THOMAS, RG ;
COX, WR .
CIRCULATION, 1988, 77 (02) :372-379
[5]   LONG-TERM CLINICAL AND ANGIOGRAPHIC FOLLOW-UP OF PATIENTS TREATED WITH THE SELF-EXPANDING CORONARY STENT FOR ACUTE OCCLUSION DURING BALLOON ANGIOPLASTY OF THE RIGHT CORONARY-ARTERY [J].
GOY, JJ ;
SIGWART, U ;
VOGT, P ;
STAUFFER, JC ;
KAPPENBERGER, L .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (07) :1593-1596
[6]  
HAUDE M, 1991, BRIT HEART J, V66, P337
[7]   EMERGENT USE OF BALLOON-EXPANDABLE CORONARY-ARTERY STENTING FOR FAILED PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY [J].
HERRMANN, HC ;
BUCHBINDER, M ;
CLEMEN, MW ;
FISCHMAN, D ;
GOLDBERG, S ;
LEON, MB ;
SCHATZ, RA ;
TIERSTEIN, P ;
WALKER, CM ;
HIRSHFELD, JW .
CIRCULATION, 1992, 86 (03) :812-819
[8]  
JAEGERE PP, 1992, AM J CARDIOL, V69, P598
[9]   CORONARY STENTING FOR TREATMENT OF ACUTE OR THREATENED CLOSURE FOLLOWING DISSECTION AFTER CORONARY BALLOON ANGIOPLASTY [J].
MAIELLO, L ;
COLOMBO, A ;
GIANROSSI, R ;
MCCANNY, R ;
FINCI, L .
AMERICAN HEART JOURNAL, 1993, 125 (06) :1570-1575
[10]   ASSESSMENT OF STENOSES IN CORONARY ANGIOPLASTY - INTEROBSERVER AND INTRAOBSERVER VARIABILITY [J].
MEIER, B ;
GRUENTZIG, AR ;
GOEBEL, N ;
PYLE, R ;
VONGOSSLAR, W ;
SCHLUMPF, M .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 1983, 3 (02) :159-169