Micro computed tomography for vascular exploration

被引:89
作者
Zagorchev, Lyubomir [1 ,2 ,3 ,4 ]
Oses, Pierre [5 ,6 ]
Zhuang, Zhen W. [7 ]
Moodie, Karen [1 ,2 ]
Mulligan-Kehoe, Mary Jo [1 ,8 ,9 ]
Simons, Michael [7 ]
Couffinhal, Thierry [5 ,6 ]
机构
[1] Dartmouth Med Sch, Heart & Vasc Res Ctr, Lebanon, NH 03755 USA
[2] Dartmouth Med Sch, Cardiol Sect, Lebanon, NH 03755 USA
[3] Dartmouth Med Sch, Radiol, Lebanon, NH 03755 USA
[4] Philips Res North Amer, Clin Sites Res Program, Briarcliff Manor, NY 02141 USA
[5] Univ Bordeaux 2, Inserm U828, Plateforme Innovat Biotechnol Xavier Amozan, Pessac, France
[6] Univ Bordeaux 2, CHU Bordeaux, Pole Cardiothorac, Pessac, France
[7] Yale Univ, Sch Med, New Haven, CT 06520 USA
[8] Dartmouth Med Sch, Dept Surg, Lebanon, NH 03755 USA
[9] Dartmouth Med Sch, Dept Vasc Sect, Lebanon, NH 03755 USA
来源
VASCULAR CELL | 2010年 / 2卷
关键词
D O I
10.1186/2040-2384-2-7
中图分类号
Q813 [细胞工程];
学科分类号
摘要
Vascular exploration of small animals requires imaging hardware with a very high spatial resolution, capable of differentiating large as well as small vessels, in both in vivo and ex vivo studies. Micro Computed Tomography (micro-CT) has emerged in recent years as the preferred modality for this purpose, providing high resolution 3D volumetric data suitable for analysis, quantification, validation, and visualization of results. The usefulness of micro-CT, however, can be adversely affected by a range of factors including physical animal preparation, numerical quantification, visualization of results, and quantification software with limited possibilities. Exacerbating these inherent difficulties is the lack of a unified standard for micro-CT imaging. Most micro-CT today is aimed at particular applications and the software tools needed for quantification, developed mainly by imaging hardware manufacturers, lack the level of detail needed to address more specific aims. This review highlights the capabilities of micro-CT for vascular exploration, describes the current state of imaging protocols, and offers guidelines and suggestions aimed at making micro-CT more accurate, replicable, and robust.
引用
收藏
页数:11
相关论文
共 42 条
[1]  
Baish JW, 2000, CANCER RES, V60, P3683
[2]   The use of microcomputed tomography to study microvasculature in small rodents [J].
Bentley, MD ;
Ortiz, MC ;
Ritman, EL ;
Romero, JC .
AMERICAN JOURNAL OF PHYSIOLOGY-REGULATORY INTEGRATIVE AND COMPARATIVE PHYSIOLOGY, 2002, 282 (05) :R1267-R1279
[3]   Adventitial microvessel formation after coronary stenting and the effects of SU11218, a tyrosine kinase inhibitor [J].
Cheema, AN ;
Hong, T ;
Nili, N ;
Segev, A ;
Moffat, JG ;
Lipson, KE ;
Howlett, AR ;
Holdsworth, DW ;
Cole, MJ ;
Qiang, BP ;
Kolodgie, F ;
Virmani, R ;
Stewart, DJ ;
Strauss, BH .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (05) :1067-1075
[4]   Mouse models to study angiogenesis in the context of cardiovascular diseases [J].
Couffinhal, Thierry ;
Dufourcq, Pascale ;
Barandon, Laurent ;
Leroux, Lionel ;
Duplaa, Cecile .
FRONTIERS IN BIOSCIENCE-LANDMARK, 2009, 14 :3310-3325
[5]   The Antiangiogenic Activity of rPAI-123 Inhibits Vasa Vasorum and Growth of Atherosclerotic Plaque [J].
Drinane, Mary ;
Mollmark, Jessica ;
Zagorchev, Lyubomir ;
Moodie, Karen ;
Sun, Baiming ;
Hall, Amy ;
Shipman, Samantha ;
Morganelli, Peter ;
Simons, Michael ;
Mulligan-Kehoe, Mary Jo .
CIRCULATION RESEARCH, 2009, 104 (03) :337-U118
[6]   Quantitative microcomputed tomography analysis of collateral vessel development after ischemic injury [J].
Duvall, CL ;
Taylor, WR ;
Weiss, D ;
Guldberg, RE .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2004, 287 (01) :H302-H310
[7]  
Goshtasby A, 2005, 2D 2D IMAGE REGISTRA
[8]   Functional anatomy and hemodynamic characteristics of vasa vasorum in the walls of porcine coronary arteries [J].
Gössl, M ;
Rosol, M ;
Malyar, NM ;
Fitzpatrick, LA ;
Beighley, PE ;
Zamir, M ;
Ritman, EL .
ANATOMICAL RECORD PART A-DISCOVERIES IN MOLECULAR CELLULAR AND EVOLUTIONARY BIOLOGY, 2003, 272A (02) :526-537
[9]   Implementation of dual- and triple-energy cone-beam micro-CT for postreconstruction material decomposition [J].
Granton, P. V. ;
Pollmann, S. I. ;
Ford, N. L. ;
Drangova, M. ;
Holdsworth, D. W. .
MEDICAL PHYSICS, 2008, 35 (11) :5030-5042
[10]   DISTRIBUTION OF MEMBRANE THICKNESS DETERMINED BY LINEAL ANALYSIS [J].
GUNDERSEN, HJG ;
JENSEN, TB ;
OSTERBY, R .
JOURNAL OF MICROSCOPY, 1978, 113 (MAY) :27-43