SAMPLING VARIABILITY AND STORAGE STABILITY OF VOLATILE ORGANIC CONTAMINANTS

被引:2
作者
EATON, HG [1 ]
WILLIAMS, FW [1 ]
SMITH, DE [1 ]
机构
[1] DESMATICS INC,STATE COLL,PA 16801
关键词
SUBMARINES - Air Purification;
D O I
10.1093/chromsci/21.2.77
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A technique has been developed for collecting time-integrated air samples into evacuated 1. 64-l stainless steel flasks collecting with a critical orifice. Air samples were collected up to one-half atmospheric pressures. Several volatile organic contaminants were evaluated for sampling variability and storage stability over an 80-day period. The storage of the samples at one-half atmospheric pressure necessitated the development of a new technique for transferring the sample to the GC/MS for analyses.
引用
收藏
页码:77 / 84
页数:8
相关论文
共 19 条
[1]   AN ACCURATE GAS METERING SYSTEM FOR LAMINAR FLOW STUDIES [J].
ANDERSEN, JW ;
FRIEDMAN, R .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1949, 20 (01) :61-66
[2]  
BENNETT CA, 1954, STATISTICAL ANAL CHE
[3]   DETERMINATION OF ORGANIC VOLATILES IN AIR-POLLUTION STUDIES - CHARACTERIZATION OF PROFILES [J].
BERTSCH, W ;
CHANG, RC ;
ZLATKIS, A .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1974, 12 (04) :175-182
[4]  
BOX GEP, 1978, STATISTICS EXPT
[5]  
CARHART HW, 1963, NRL6053 REP, pCH8
[6]   TOTAL HYDROCARBON ANALYZER FOR USE IN NUCLEAR SUBMARINES AND OTHER CLOSED ENVIRONMENTS [J].
EATON, HG ;
UMSTEAD, ME ;
SMITH, WD .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1973, 11 (05) :275-278
[7]  
EATON HG, 1976, NRL7960 REP
[8]  
EATON HG, 1976, NRL7963 REP
[9]   COLLECTION AND ANALYSIS OF TRACE ORGANIC EMISSIONS FROM NATURAL SOURCES [J].
HOLZER, G ;
SHANFIELD, H ;
ZLATKIS, A ;
BERTSCH, W ;
JUAREZ, P ;
MAYFIELD, H ;
LIEBICH, HM .
JOURNAL OF CHROMATOGRAPHY, 1977, 142 (NOV) :755-764
[10]  
NESTER FHM, 1958, NRL866 REP