POLAROGRAPHY OF PENEM CARBAPENEM ANTIBIOTICS AND THE AZETIDINONE INTERMEDIATE

被引:8
作者
BERSIER, PM
BERSIER, J
SEDELMEIER, G
HUNGERBUHLER, E
机构
[1] CIBA GEIGY AG, CENT RES LABS, CH-4002 BASEL, SWITZERLAND
[2] CIBA GEIGY AG, PHARMACEUT RES & DEV, CH-4002 BASEL, SWITZERLAND
[3] CIBA GEIGY AG, RES DEPT, DIV PHARMACEUT, CH-4002 BASEL, SWITZERLAND
关键词
D O I
10.1002/elan.1140020508
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Various penems, structurally closely related carbapenems, and the intermediate 4‐acetoxyazetidin‐2‐one were studied by direct current sampled dc, differential pulse polarography (DPP), cyclic voltammetry, and ac tensammetry. Optimum pH ranges for the determination of 4‐acetoxyazetidin‐2‐one and the various penems are discussed. In Britton—Robinson buffer (BRP) penems exhibit (pH 3) one stable reduction wave, which can be exploited analytically. Carbapenems exhibit stability problems in BRP (pH 3). They can be determined after conversion by hydrolysis into a stable imine form. Useful linear concentration ranges are 10 to 140 μg/mL for 4‐acetoxyazetidin‐2‐one and 20 to 170 and 0.5 to 70 μg/mL for penems using dc polarography and DPP, respectively. The precision of the proposed analytical methods is acceptable, with relative standard deviations around 2.5% for the assay of 4‐acetoxyazetidin‐2‐one and 2.5 and 2–5% for the penem and carbapenem, respectively. Copyright © 1990 VCH Publishers, Inc.
引用
收藏
页码:373 / 381
页数:9
相关论文
共 37 条
[1]   POLAROGRAPHY, VOLTAMMETRY AND TENSAMMETRY - TOOLS FOR DAY-TO-DAY ANALYSIS IN THE INDUSTRIAL LABORATORY [J].
BERSIER, PM ;
BERSIER, J .
ANALYST, 1989, 114 (12) :1531-1544
[2]  
BERSIER PM, IN PRESS POLAROGRAPH
[3]  
BERSIER PM, 1988, APR KEYN LECT LOUGHB
[4]   DETERMINATION OF N-FORMIMIDOYLTHIENAMYCIN CONCENTRATION IN SERA FROM PEDIATRIC-PATIENTS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BLOH, AM ;
CAMPOS, JM ;
ALPERT, G ;
PLOTKIN, SA .
JOURNAL OF CHROMATOGRAPHY, 1986, 375 (02) :444-450
[5]  
DURCKHEIMER W, 1985, ANGEW CHEM, V97, P183
[6]  
ERNEST I, 1982, CHEM BIOL BETA LACTA, V2, P315
[7]   DIFFERENTIAL-PULSE POLAROGRAPHIC-DETERMINATION OF DEGRADATION PRODUCTS OF CEPHALOSPORINS - COMPARISON OF THE DEGRADATION OF CEPHALOGLYCIN IN NEUTRAL SOLUTION WITH THAT OF CEPHALEXIN [J].
FOGG, AG ;
MARTIN, MJ .
ANALYST, 1981, 106 (1268) :1213-1217
[8]   DIFFERENTIAL PULSE POLAROGRAPHIC-DETERMINATION OF CEPHALOSPORINS AND THEIR DEGRADATION PRODUCTS [J].
FOGG, AG ;
FAYAD, NM ;
BURGESS, C ;
MCGLYNN, A .
ANALYTICA CHIMICA ACTA, 1979, 108 (JUL) :205-211
[9]  
FOGG AG, 1980, ANAL CHEM SYMP SER, V2, P233
[10]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF THE PENEM ANTIBIOTIC (5R,6S)-2-AMINOMETHYL-6-[(1R)-HYDROXYETHYL]-2-PENEM-3-CARBOXYLIC ACID IN HUMAN-PLASMA AND URINE [J].
GODBILLON, J ;
DUVAL, M ;
GAURON, S ;
DUBOIS, JP .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 427 (02) :269-276