HUMAN PRESSURE PERCEPTION VALUES FOR CONSTANT AND MOVING ONE-POINT AND 2-POINT DISCRIMINATION

被引:140
作者
DELLON, ES
MOUREY, R
DELLON, AL
机构
[1] JOHNS HOPKINS UNIV,DIV PLAST SURG,BALTIMORE,MD 21218
[2] JOHNS HOPKINS UNIV,DIV REHABIL MED,BALTIMORE,MD 21218
[3] JOHNS HOPKINS UNIV,DEPT NEUROL SURG,BALTIMORE,MD 21218
关键词
D O I
10.1097/00006534-199207000-00017
中图分类号
R61 [外科手术学];
学科分类号
摘要
Despite the need to evaluate sensibility for accurate diagnosis and the need to record the degree of sensation achieved in the postoperative period, the clinician has been without the ability to measure human pressure perception accurately. Traditionally, the Semmes-Weinstein monofilaments were used to measure the static one-point discrimination threshold. A new sensory testing instrument, the Pressure-Specifying Sensory Device, was used to obtain normative data from the index and little finger of the dominant hand in 35 people ranging in age from 16 to 83 with no known neurologic impairment. Pressure perceptions for static one- and two-point discrimination (s1PD, s2PD) and moving one- and two-point discrimination (m1PD, m2PD) were recorded. The mean values (+/-SD) were 0.13 +/- 0.06, 0.24 +/- 0.12, 0.22 +/- 0.10, and 0.26 +/- 0.13 gm/mm2 for s1PD, s2PD, m1PD, and m2PD, respectively, on the index finger and 0.07 +/- 0.05, 0.16 +/- 0.12, 0.17 +/- 0.07, and 0.21 +/- 0.14 gm/mm2 for s1PD, s2PD, m1PD, and m2PD, respectively, for the little finger. The little finger was significantly more sensitive than the index finger (p < 0.001). There was no significant change in pressure perception with increasing age.
引用
收藏
页码:112 / 117
页数:6
相关论文
共 22 条
[1]  
BELL JA, 1984, REHABILITATION HAND, P399
[2]   THE REPEATABILITY OF TESTING WITH SEMMES-WEINSTEIN MONOFILAMENTS [J].
BELLKROTOSKI, J ;
TOMANCIK, E .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1987, 12A (01) :155-161
[3]   THE FINE STRUCTURE OF MEISSNERS TOUCH CORPUSCLES OF HUMAN FINGERS [J].
CAUNA, N ;
ROSS, LL .
JOURNAL OF BIOPHYSICAL AND BIOCHEMICAL CYTOLOGY, 1960, 8 (02) :467-482
[4]  
Dellon A L, 1978, J Hand Surg Am, V3, P474
[5]  
DELLON AL, 1980, PLAST RECONSTR SURG, V65, P466, DOI 10.1097/00006534-198004000-00011
[6]   THE SENSATIONAL CONTRIBUTIONS OF MOBERG,ERIK [J].
DELLON, AL .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1990, 15B (01) :14-24
[7]   THE VIBROMETER [J].
DELLON, AL .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1983, 71 (03) :427-431
[8]  
Dellon AL, 1981, EVALUATION SENSIBILI
[9]  
GELLIS M, 1977, PLAST RECONSTR SURG, V59, P57
[10]  
GROSSMAN J, 1986, 31ST ANN M PLAST SUR