VELOCITY DISTRIBUTION MODEL FOR NORMAL BLOOD-FLOW IN THE HUMAN ASCENDING AORTA

被引:9
作者
SEGADAL, L
机构
[1] Department of Surgery, Section of Thoracic and Cardiovascular Surgery, Haukeland Hospital, University of Bergen, Bergen
关键词
AORTA; AORTIC PHYSIOLOGY; BLOOD FLOW VELOCITY;
D O I
10.1007/BF02442319
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
During the study of velocities in the human ascending aorta it became necessary to establish a method for two-dimensional velocity profiles from discrete velocity data obtained from different heartbeats and with different techniques. A descriptive geometrical model was therefore developed and expanded to 16 elements each containing 16 constants by a serial optimising technique using a least-squares method. Published data from two different studies on velocity distribution in the ascending aorta comprising six subjects with normal aortic valves were used. Three-dimensional graphic displays of velocity profile at different time intervals of the heart cycle clearly show common features of distribution of velocity at a point 6 cm above the aortic valve. There was a pronounced skewness with clockwise rotation of the skewness direction during systole, reversed flow directed towards the left coronary sinus of Valsalva in late systole and early diastole concomitant with secondary flow augmentation along the opposite wall of the aorta. Consistent plane-symmetric features during the heart cycle could not be demonstrated.
引用
收藏
页码:489 / 492
页数:4
相关论文
共 13 条
[1]  
CHENEY EW, 1985, NUMERICAL MATH COMPU
[2]  
Hatle L, 1982, DOPPLER ULTRASOUND C
[3]   A COMPARISON BETWEEN SINGLE GATE AND MULTIGATE ULTRASONIC DOPPLER MEASUREMENTS FOR THE ASSESSMENT OF THE VELOCITY PATTERN IN THE HUMAN ASCENDING AORTA [J].
JENNI, R ;
VIELI, A ;
RUFFMANN, K ;
KRAYENBUEHL, HP ;
ANLIKER, M .
EUROPEAN HEART JOURNAL, 1984, 5 (11) :948-953
[4]   A REMOVABLE EXTRALUMINAL DOPPLER PROBE FOR CONTINUOUS MONITORING OF CHANGES IN CARDIAC-OUTPUT [J].
KEAGY, BA ;
LUCAS, CL ;
HSIAO, HS ;
WILCOX, BR .
JOURNAL OF ULTRASOUND IN MEDICINE, 1983, 2 (08) :357-362
[5]  
KLIPSTEIN RH, 1987, BRIT HEART J, V58, P316
[6]   THE VELOCITY PROFILE IN THE CANINE ASCENDING AORTA AND ITS EFFECTS ON THE ACCURACY OF PULSED DOPPLER DETERMINATIONS OF MEAN BLOOD VELOCITY [J].
LUCAS, CL ;
KEAGY, BA ;
HSIAO, HS ;
JOHNSON, TA ;
HENRY, GW ;
WILCOX, BR .
CARDIOVASCULAR RESEARCH, 1984, 18 (05) :282-293
[7]   CONTINUOUS MEASUREMENT OF AORTIC BLOOD VELOCITY, AFTER CARDIAC-SURGERY, BY MEANS OF AN EXTRACTABLE DOPPLER ULTRASOUND PROBE [J].
MATRE, K ;
SEGADAL, L ;
ENGEDAL, H .
JOURNAL OF BIOMEDICAL ENGINEERING, 1985, 7 (02) :84-88
[8]  
MCDONALD DA, 1974, BLOOD FLOW ARTERIES, P101
[9]   3-DIMENSIONAL VISUALIZATION OF VELOCITY PROFILES IN THE ASCENDING AORTA IN DOGS, MEASURED WITH A HOT-FILM ANEMOMETER [J].
PAULSEN, PK ;
HASENKAM, JM .
JOURNAL OF BIOMECHANICS, 1983, 16 (03) :201-210
[10]   VELOCITY PATTERNS IN AORTA [J].
SEED, WA ;
WOOD, NB .
CARDIOVASCULAR RESEARCH, 1971, 5 (03) :319-&