QUANTITATIVE PLASMA D-DIMER LEVELS AMONG PATIENTS UNDERGOING PULMONARY ANGIOGRAPHY FOR SUSPECTED PULMONARY-EMBOLISM

被引:114
作者
GOLDHABER, SZ
SIMONS, GR
ELLIOTT, CG
HAIRE, WD
TOLTZIS, R
BLACKLOW, SC
DOOLITTLE, MH
WEINBERG, DS
机构
[1] HARVARD UNIV,BRIGHAM & WOMENS HOSP,SCH MED,DEPT PATHOL,BOSTON,MA 02115
[2] LATTER DAY ST HOSP,SALT LAKE CITY,UT 84143
[3] UNIV NEBRASKA,MED CTR,OMAHA,NE 68105
[4] CHRIST HOSP,CINCINNATI,OH 45219
来源
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION | 1993年 / 270卷 / 23期
关键词
D O I
10.1001/jama.270.23.2819
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective.-To test the hypothesis that a low D-dimer level has a high negative predictive value for acute pulmonary embolism (PE) among patients undergoing diagnostic pulmonary angiography. Design.-Blinded comparison of quantitative plasma D-dimer levels, measured using a monoclonal antibody assay, with pulmonary angiographic results from 173 patients with suspected acute PE. Setting.-Tertiary care setting at four participating institutions. Patients.-Plasma samples were analyzed in 173 patients who underwent diagnostic pulmonary arteriography for suspected acute PE. Main Outcome Measures.-Sensitivity, specificity, and predictive values of quantitative plasma D-dimer levels for the diagnosis of PE, using pulmonary angiographic data as the criterion standard test. Results.-Of 35 patients with D-dimer values less than 500 ng/mL, only three had abnormal pulmonary angiograms. The negative predictive value of a plasma D-dimer level less than 500 ng/mL for acute PE was 91.4% (95% confidence interval [CI], 76.9% to 98.2%). D-dimer levels were greater than 500 ng/mL in 42 of 45 patients with PE and in 96 of 128 patients without PE (P=.016). Sensitivity, specificity, and positive predictive value of a plasma D-dimer level greater than 500 ng/mL for acute PE were 93.3% (95% CI, 81.7% to 98.6%), 25.0% (95% CI, 17.5% to 32.5%), and 30.4% (95% CI, 22.8% to 38.1%), respectively. Conclusions.-The results of our study indicate that quantitative plasma D-dimer levels can be useful in screening patients with suspected PE who require. pulmonary angiography. Plasma D-dimer values less than 500 ng/mL may obviate the need for pulmonary angiography, particularly among medical patients for whom the clinical suspicion of PE is low. The plasma D-dimer value, assayed using a commercially available enzyme-linked immunosorbent assay kit, is a sensitive but nonspecific test for the presence of acute PE.
引用
收藏
页码:2819 / 2822
页数:4
相关论文
共 15 条
[1]   MEASUREMENT OF D-DIMER IN PLASMA AS DIAGNOSTIC-AID IN SUSPECTED PULMONARY-EMBOLISM [J].
BOUNAMEAUX, H ;
CIRAFICI, P ;
DEMOERLOOSE, P ;
SCHNEIDER, PA ;
SLOSMAN, D ;
REBER, G ;
UNGER, PF .
LANCET, 1991, 337 (8735) :196-200
[2]  
Bounameaux H, 1990, Blood Coagul Fibrinolysis, V1, P577, DOI 10.1097/00001721-199010000-00045
[3]  
BOUNAMEAUX H, 1988, LANCET, V2, P628
[4]  
BOUNAMEAUX H, 1992, SANG THROMBOSE VAISS, V4, P255
[5]  
ELMS MJ, 1983, THROMB HAEMOSTASIS, V50, P591
[6]   MONOCLONAL-ANTIBODIES TO CROSSLINKED FIBRIN DEGRADATION PRODUCTS (XL-FDP) .2. EVALUATION IN A VARIETY OF CLINICAL CONDITIONS [J].
GAFFNEY, PJ ;
CREIGHTON, LJ ;
CALLUS, M ;
THORPE, R .
BRITISH JOURNAL OF HAEMATOLOGY, 1988, 68 (01) :91-96
[7]  
Gardner M. J., 1989, BRIT MED J
[8]   UTILITY OF CROSS-LINKED FIBRIN DEGRADATION PRODUCTS IN THE DIAGNOSIS OF PULMONARY-EMBOLISM [J].
GOLDHABER, SZ ;
VAUGHAN, DE ;
TUMEH, SS ;
LOSCALZO, J .
AMERICAN HEART JOURNAL, 1988, 116 (02) :505-508
[9]   SERUM CROSSLINKED FIBRIN (XDP) AND FIBRINOGEN FIBRIN DEGRADATION PRODUCTS (FDP) IN DISORDERS ASSOCIATED WITH ACTIVATION OF THE COAGULATION OR FIBRINOLYTIC SYSTEMS [J].
HUNT, FA ;
RYLATT, DB ;
HART, RA ;
BUNDESEN, PG .
BRITISH JOURNAL OF HAEMATOLOGY, 1985, 60 (04) :715-722
[10]   PULMONARY-EMBOLISM - EFFICACY OF D-DIMER AND THROMBIN-ANTITHROMBIN ILL COMPLEX DETERMINATIONS AS SCREENING-TESTS BEFORE LUNG-SCANNING [J].
LEITHA, T ;
SPEISER, W ;
DUDCZAK, R .
CHEST, 1991, 100 (06) :1536-1541