Microbiosensors based on carbon and platinum fibers are described. Carbon fibers were used to construct microelectrodes of 7 mum diameter. Electrochemical operations for pre-electrolysis and measuring were examined for the highly sensitive determination of hydrogen peroxide. A triangular potential (-2 to +2 V vs. Ag/AgCl) was applied before measuring each pair of double pulses (first pulse: 750 mV; second pulse: 1100 mV). The determination limit was 0.1 muM of hydrogen peroxide. The reproducible determination of hydrogen peroxide is possible even in samples containing albumin protein. The separation of hydrogen peroxide from ascorbic acid is also possible because the oxidation potential of ascorbic acid is different from that of hydrogen peroxide. An acetylcholine microsensor was fabricated by immobilizing acetylcholine esterase and choline oxidase on the carbon fiber by entrapment with poly(vinyl alcohol)-quarternized stilbazole (PVA-SbQ). This sensor gave a linear calibration plot for the range 0.1-1.0 mM with a linear correlation coefficient of 0.9842. Glucose oxidase (GOD) and glucose dehydrogenase (GDH) immobilized cylindrical platinum microelectrodes were fabricated, and their characteristics were evaluated, respectively, by using 1,4-benzoquinone (BQ) and ferricyanide as electron mediators. Each enzyme was immobilized by using PVA-SbQ on a cylindrical microelectrode of 2 mum diameter. A linear range in the calibration curve of the GOD-based glucose microsensor was observed to be wider than that obtained using a disk electrode of 1 mm diameter. The mediated response of the 2 mum glucose sensor was compared with the response resulting from hydrogen peroxide detection. This result showed that a higher response and a wider linear range were observed with highly concentrated mediator. A much higher response of the GDH immobilized 2 mum microelectrode was obtained when not only ferricyanide but also diaphorase was employed to reoxidize the NADH produced by the enzyme reaction of GDH. The GDH-based glucose microsensor was found to be unaffected by the concentration of dissolved oxygen.
引用
收藏
页码:219 / 228
页数:10
相关论文
共 36 条
[1]   INTRACELLULAR ANALYSIS WITH AN IMMOBILIZED-ENZYME GLUCOSE ELECTRODE HAVING A 2-MU-M DIAMETER AND SUBSECOND RESPONSE-TIMES [J].
ABE, T ;
LAU, YY ;
EWING, AG .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1991, 113 (19) :7421-7423
[2]   INVITRO MEASUREMENT OF DOPAMINE CONCENTRATION WITH CARBON-FIBER ELECTRODE [J].
AKIYAMA, A ;
KATO, T ;
ISHII, K ;
YASUDA, E .
ANALYTICAL CHEMISTRY, 1985, 57 (08) :1518-1522
[3]   AN ORGANIC CONDUCTOR ELECTRODE FOR THE OXIDATION OF NADH [J].
ALBERY, WJ ;
BARTLETT, PN .
JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1984, (04) :234-236
[4]   ELECTRODE-KINETICS OF THE OXIDATION OF HYDROGEN-PEROXIDE AT PRETREATED GLASSY-CARBON AND CARBON-FIBER ELECTRODES [J].
AOKI, K ;
ISHIDA, M ;
TOKUDA, K ;
HASEBE, K .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 251 (01) :63-71
[5]   STEADY-STATE VOLTAMMETRY [J].
BOND, AM ;
OLDHAM, KB ;
ZOSKI, CG .
ANALYTICA CHIMICA ACTA, 1989, 216 (1-2) :177-230
[6]   ULTRAMICROELECTRODE SENSORS AND DETECTORS - CONSIDERATIONS OF THE STABILITY, SENSITIVITY, REPRODUCIBILITY, AND MECHANISM OF ION-TRANSPORT IN GAS-PHASE CHROMATOGRAPHY AND IN HIGH-PERFORMANCE LIQUID-PHASE CHROMATOGRAPHY [J].
BRINA, R ;
PONS, S ;
FLEISCHMANN, M .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 244 (1-2) :81-90
[7]   DETERMINATION OF CHOLINE-CONTAINING PHOSPHOLIPIDS IN HUMAN BILE AND SERUM BY A NEW ENZYME SENSOR [J].
CAMPANELLA, L ;
MASCINI, M ;
PALLESCHI, G ;
TOMASSETTI, M .
CLINICA CHIMICA ACTA, 1985, 151 (01) :71-83
[8]   ENZYME SENSOR FOR THE DETERMINATION OF CHOLINE-CONTAINING PHOSPHOLIPIDS IN SOME BIOLOGICAL-FLUIDS [J].
CAMPANELLA, L ;
TOMASSETTI, M ;
SAMMARTINO, MP .
ANALYST, 1988, 113 (01) :77-80
[9]   FIELD-EFFECT TRANSISTOR SENSITIVE TO PENICILLIN [J].
CARAS, S ;
JANATA, J .
ANALYTICAL CHEMISTRY, 1980, 52 (12) :1935-1937
[10]   POLYMER-MODIFIED, CARBON-FIBER MICROELECTRODES AS CATECHOL SENSORS [J].
COURY, LA ;
HUBER, EW ;
BIRCH, EM ;
HEINEMAN, WR .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1989, 136 (04) :1044-1049