PREVENTION OF THE RAPID DEGRADATION OF SUBCUTANEOUSLY IMPLANTED AG/AGCL REFERENCE ELECTRODES USING POLYMER-COATINGS

被引:97
作者
MOUSSY, F [1 ]
HARRISON, DJ [1 ]
机构
[1] UNIV ALBERTA,SURG MED RES INST,EDMONTON T6G 2N8,AB,CANADA
关键词
D O I
10.1021/ac00077a015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
To assess the effect of the biological response to implanted Ag/AgCl reference electrodes on the electrode stability, uncoated and polymer-coated Ag/AgCl electrodes were implanted subcutaneously in rats. After 1 week of implantation, uncoated Ag/AgCl electrode potentials, measured in 0.1 M KCI, shifted by about -180 mV, and both voltammetry and electron microscopy showed that all the AgCl was removed. The electrodes could be significantly protected by coating with polyurethane or a perfluorinated ionomer (Nafion) cured at 120 degrees C for 1 h. Electron micrographs showed the 120 degrees C cured Nafion and polyurethane coatings remained intact over 2 weeks of implantation. Following 2 weeks of implantation the cured, Nafion-coated electrodes' potentials were shifted by -15 +/- 7 mV relative to the initial values. Voltammetry showed that they were still not polarizable. The current densities obtained with the coated reference electrodes are sufficient for their use as counter/pseudoreference electrodes with implantable two-electrode glucose sensor systems. The tissue response to coated electrodes was minimal in comparison to the response to uncoated reference electrodes.
引用
收藏
页码:674 / 679
页数:6
相关论文
共 21 条
[1]   DESIGN AND INVITRO STUDIES OF A NEEDLE-TYPE GLUCOSE SENSOR FOR SUBCUTANEOUS MONITORING [J].
BINDRA, DS ;
ZHANG, YN ;
WILSON, GS ;
STERNBERG, R ;
THEVENOT, DR ;
MOATTI, D ;
REACH, G .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1692-1696
[2]  
BLUM L, 1991, BIOSENSORS PRINCIPLE
[3]  
CLARK LC, 1988, METHOD ENZYMOL, V137, P68
[4]   BRAIN TISSUE REACTION TO SOME CHRONICALLY IMPLANTED METALS [J].
DYMOND, AM ;
KAECHELE, LE ;
JURIST, JM ;
CRANDALL, PH .
JOURNAL OF NEUROSURGERY, 1970, 33 (05) :574-&
[5]  
EISENBERG A, 1982, ACS S SERIES, V180
[6]   PHYSIOLOGICAL PREPARATION FOR STUDYING THE RESPONSE OF SUBCUTANEOUSLY IMPLANTED GLUCOSE AND OXYGEN SENSORS [J].
ERTEFAI, S ;
GOUGH, DA .
JOURNAL OF BIOMEDICAL ENGINEERING, 1989, 11 (05) :362-368
[7]   PERMEABILITY OF GLUCOSE AND OTHER NEUTRAL SPECIES THROUGH RECAST PERFLUOROSULFONATED IONOMER FILMS [J].
FAN, ZH ;
HARRISON, DJ .
ANALYTICAL CHEMISTRY, 1992, 64 (11) :1304-1311
[8]   STRUCTURE AND RELATED PROPERTIES OF SOLUTION-CAST PERFLUOROSULFONATED IONOMER FILMS [J].
GEBEL, G ;
ALDEBERT, P ;
PINERI, M .
MACROMOLECULES, 1987, 20 (06) :1425-1428
[9]   CHARACTERIZATION OF PERFLUOROSULFONIC ACID POLYMER COATED ENZYME ELECTRODES AND A MINIATURIZED INTEGRATED POTENTIOSTAT FOR GLUCOSE ANALYSIS IN WHOLE-BLOOD [J].
HARRISON, DJ ;
TURNER, RFB ;
BALTES, HP .
ANALYTICAL CHEMISTRY, 1988, 60 (19) :2002-2007
[10]  
JACKSON WF, 1983, CIRC RES, P105