ON-LINE ELECTROCHEMICAL DETECTION FOR SUPERCRITICAL-FLUID CHROMATOGRAPHY

被引:23
作者
DRESSMAN, SF [1 ]
MICHAEL, AC [1 ]
机构
[1] UNIV PITTSBURGH,DEPT CHEM,PITTSBURGH,PA 15260
关键词
D O I
10.1021/ac00104a007
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A self-contained electrochemical cell consisting of a working and a quasi-reference electrode coated with a thin film of a conductive polymer was used as a postcolumn detector for supercritical fluid chromatography (SFC-EC). Cyclic voltammetry was used to obtain chromatograms of ferrocene, anthracene, p-benzoquinone, and hydroquinone after their elution from a Cls packed column with unmodified, acetonitrile-modified, or methanol-modified CO2. In unmodified CO2, the quantitative performance of the SFC-EC detection of ferrocene was similar to that obtained with a downstream mo with respect to detection limit, response linearity, and peak shape. The baseline signal of the EC detector remained hat during density gradient elution while a noticeable drift occurred in the baseline signal of the FID. Furthermore, whereas the mo was totally inoperable in a mobile phase containing similar to 3% (v/v) Of either acetonitrile or methanol, the EC detector functioned well in the modified fluids. Thus, the EC detector is compatible with both unmodified and modified CO2 mobile phases. A valuable feature of these newly developed SFC detectors is their compatibility with a very large fraction of the range of separation conditions that are important to SFC.
引用
收藏
页码:1339 / 1345
页数:7
相关论文
共 27 条
[1]  
Angus S., 1976, INT THERMODYNAMIC TA
[2]   SOLUBILITY OF SOLIDS AND LIQUIDS IN SUPERCRITICAL GASES [J].
CHRASTIL, J .
JOURNAL OF PHYSICAL CHEMISTRY, 1982, 86 (15) :3016-3021
[3]   QUANTITATIVE-DETERMINATION OF CATECHOLAMINES IN INDIVIDUAL BOVINE ADRENOMEDULLARY CELLS BY REVERSED-PHASE MICROCOLUMN LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
COOPER, BR ;
JANKOWSKI, JA ;
LESZCZYSZYN, DJ ;
WIGHTMAN, RM ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1992, 64 (06) :691-694
[4]   ELECTROCHEMICAL DETECTION SYSTEM FOR SUPERCRITICAL FLUID CHROMATOGRAPHY [J].
DIMASO, M ;
PURDY, WC ;
MCCLINTOCK, SA .
JOURNAL OF CHROMATOGRAPHY, 1990, 519 (01) :256-262
[5]   CHARACTERIZATION OF THE ELECTROENZYMATIC REDUCTION OF H2O2 IN CARBON-DIOXIDE BY VOLTAMMETRY WITH A CHEMICALLY-MODIFIED MICROELECTRODE [J].
DRESSMAN, SF ;
GARGUILO, MG ;
SULLENBERGER, EF ;
MICHAEL, AC .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1993, 115 (16) :7541-7542
[6]   ELECTROCHEMICAL DETECTION IN MICROCOLUMN SEPARATIONS [J].
EWING, AG ;
MESAROS, JM ;
GAVIN, PF .
ANALYTICAL CHEMISTRY, 1994, 66 (09) :A527-A537
[7]   COMPUTER-ASSISTED RAPID-SCAN CYCLIC STAIRCASE VOLTAMMETRY IN NORMAL-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
GUNASINGHAM, H ;
TAY, BT ;
ANG, KP .
ANALYTICAL CHEMISTRY, 1987, 59 (02) :262-266
[8]   END-COLUMN DETECTION FOR CAPILLARY ZONE ELECTROPHORESIS [J].
HUANG, XH ;
ZARE, RN ;
SLOSS, S ;
EWING, AG .
ANALYTICAL CHEMISTRY, 1991, 63 (02) :189-192
[9]   SOME ASPECTS OF CAPILLARY SUPERCRITICAL FLUID CHROMATOGRAPHY [J].
JANSSEN, HG ;
CRAMERS, CA .
JOURNAL OF CHROMATOGRAPHY, 1990, 505 (01) :19-35
[10]   ELECTROCHEMISTRY OF POLYMER-FILMS NOT IMMERSED IN SOLUTION - ELECTRON-TRANSFER ON AN ION BUDGET [J].
JERNIGAN, JC ;
CHIDSEY, CED ;
MURRAY, RW .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1985, 107 (09) :2824-2826