AMPEROMETRIC GLUCOSE MICROELECTRODES PREPARED THROUGH IMMOBILIZATION OF GLUCOSE-OXIDASE IN REDOX HYDROGELS

被引:150
作者
PISHKO, MV [1 ]
MICHAEL, AC [1 ]
HELLER, A [1 ]
机构
[1] UNIV TEXAS, DEPT CHEM ENGN, AUSTIN, TX 78712 USA
关键词
D O I
10.1021/ac00020a014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Glucose microelectrodes have been formed with glucose oxidase immobilized in poly[(vinylpyridine)Os(bipyridine)2Cl] derivative-based redox hydrogels on beveled carbon-fiber microdisk (7-mu-m diameter) electrodes. In the resulting microelectrode, the steady-state glucose electrooxidation current density is 0.3 mA cm-2 and the sensitivity is 20 mA cm-2 M-1. The current density and sensitivity are 10 times higher than in macroelectrodes made with the same hydrogel. Furthermore, the current is less affected by a change in the partial pressure of oxygen. The higher current density and lower oxygen sensitivity point to the efficient collection of electrons through their diffusion in the redox hydrogel to the electrode surface. These results contrast with those observed for enzyme electrodes based on diffusing mediators, where loss of the enzyme-reduced mediator by radial diffusion to the solution decreases the current densities of microelectrodes relative to similar macroelectrodes.
引用
收藏
页码:2268 / 2272
页数:5
相关论文
共 31 条
[1]  
ALLEN H, 1989, ACS SYM SER, V403, P105
[2]   ELECTRON-TRANSFER THROUGH REDOX POLYMER-FILMS [J].
ANDRIEUX, CP ;
SAVEANT, JM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1980, 111 (2-3) :377-381
[3]   RESPONSE OF MICROVOLTAMMETRIC ELECTRODES TO HOMOGENEOUS CATALYTIC AND SLOW HETEROGENEOUS CHARGE-TRANSFER REACTIONS [J].
DAYTON, MA ;
EWING, AG ;
WIGHTMAN, RM .
ANALYTICAL CHEMISTRY, 1980, 52 (14) :2392-2396
[4]  
FREDERICK KR, 1990, J BIOL CHEM, V265, P3793
[5]   Solid-State Voltammetric Measurement of Plasticization Transport Enhancement in Ionically Conducting Poly(ethylene oxide) Films [J].
Geng, L. ;
Longmire, M. L. ;
Reed, R. A. ;
Parcher, J. F. ;
Barbour, C. J. ;
Murray, Royce W. .
CHEMISTRY OF MATERIALS, 1989, 1 (01) :58-63
[6]   CHEMICAL PHENOMENA IN SOLID-STATE VOLTAMMETRY IN POLYMER SOLVENTS [J].
GENG, L ;
REED, RA ;
KIM, MH ;
WOOSTER, TT ;
OLIVER, BN ;
EGEKEZE, J ;
KENNEDY, RT ;
JORGENSON, JW ;
PARCHER, JF ;
MURRAY, RW .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1989, 111 (05) :1614-1619
[7]   A PLANAR GLUCOSE ENZYME ELECTRODE [J].
GERNET, S ;
KOUDELKA, M ;
DEROOIJ, NF .
SENSORS AND ACTUATORS, 1989, 17 (3-4) :537-540
[8]  
GOUGH DA, 1988, HORM METAB RES, V20, P30
[9]   PROGRESS TOWARD A POTENTIALLY IMPLANTABLE, ENZYME-BASED GLUCOSE SENSOR [J].
GOUGH, DA ;
LEYPOLDT, JK ;
ARMOUR, JC .
DIABETES CARE, 1982, 5 (03) :190-198
[10]   REDOX POLYMER-FILMS CONTAINING ENZYMES .1. A REDOX-CONDUCTING EPOXY CEMENT - SYNTHESIS, CHARACTERIZATION, AND ELECTROCATALYTIC OXIDATION OF HYDROQUINONE [J].
GREGG, BA ;
HELLER, A .
JOURNAL OF PHYSICAL CHEMISTRY, 1991, 95 (15) :5970-5975