A KINETIC SPECTROPHOTOMETRIC METHOD TO DETERMINE THE INSECTICIDE METHYL PARATHION IN COMMERCIAL FORMULATIONS AND THE AQUEOUS ENVIRONMENT

被引:5
作者
BLANCO, CC
SANCHEZ, FG
机构
[1] Department of Analytical Chemistry, Faculty of Sciences, The University
关键词
commerical formulations; Kinetic method; methyl parathion; p-nitrophenol; spectrophotometry; water analysis;
D O I
10.1080/03067319008026953
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple kinetic-spectrophotometric method for the analysis of the organophosphate insecticide methyl parathion is presented. The method is based on the alkaline hydrolysis of the insecticide into its main metabolite p-nitrophenol. The influence of reaction variables (pH and temperature), and the effect of other pesticides, are discussed. The calibration graphs (initial rate, fixed time, fixed absorbance) were linear from 2 to 30μg/ml. The precision was calculated for the different methods applied, the relative standard deviation being 6.25 % for 4 μg/ml. The proposed kinetic method can be applied directly to synthetic mixtures, commercial formulations and different aqueous environment, with recoveries close to 100%. © 1990, Taylor & Francis Group, LLC. All rights reserved.
引用
收藏
页码:513 / 523
页数:11
相关论文
共 34 条
[1]   SYNTHETIC INORGANIC-ION EXCHANGERS AS ADSORBENTS FOR GAS-CHROMATOGRAPHY [J].
ALLULLI, S ;
TOMASSINI, N ;
BERTONI, G ;
BRUNER, F .
ANALYTICAL CHEMISTRY, 1976, 48 (08) :1259-1261
[2]  
BHASKAR SU, 1981, J ASSOC OFF ANA CHEM, V64, P1312
[3]  
BLANCO CC, 1988, ANALUSIS, V16, P215
[4]   COMPARISON OF ULTRAVIOLET AND REDUCTIVE AMPEROMETRIC DETECTION FOR DETERMINATION OF ETHYL AND METHYL PARATHION IN GREEN VEGETABLES AND SURFACE-WATER USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
CLARK, GJ ;
GOODIN, RR ;
SMILEY, JW .
ANALYTICAL CHEMISTRY, 1985, 57 (12) :2223-2228
[5]   DETERMINATION OF ORGANO-PHOSPHORUS PESTICIDES BY THIN-LAYER CHROMATOGRAPHY [J].
CURINI, M ;
LAGANA, A ;
PETRONIO, BM ;
RUSSO, MV .
TALANTA, 1980, 27 (01) :45-48
[6]   TRACE ANALYSIS FOR ORGANOTHIOPHOSPHATE AGRICULTURAL CHEMICALS BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY-PHOTOLYSIS-ELECTROCHEMICAL DETECTION [J].
DING, XD ;
KRULL, IS .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1984, 32 (03) :622-628
[7]   DEVELOPMENT OF A RADIOIMMUNOASSAY FOR PARATHION [J].
ERCEGOVICH, CD ;
VALLEJO, RP ;
GETTIG, RR ;
WOODS, L ;
BOGUS, ER ;
MUMMA, RO .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1981, 29 (03) :559-563
[8]  
FERREIRA JR, 1980, J ASSOC OFF ANA CHEM, V63, P517
[9]  
GREINKE RA, 1978, ANAL CHEM, V50, pR70, DOI 10.1021/ac50028a008
[10]   A FLUORIMETRIC KINETIC METHOD FOR DETERMINATION OF ORGANOPHOSPHORUS AND ORGANOCARBONYL COMPOUNDS [J].
GUILBAULT, GG ;
LUBRANO, GJ .
ANALYTICA CHIMICA ACTA, 1968, 43 (02) :253-+