RELATION BETWEEN REGIONAL ELECTRICAL ACTIVATION TIME AND SUBEPICARDIAL FIBER STRAIN IN THE CANINE LEFT-VENTRICLE

被引:45
作者
DELHAAS, T
ARTS, T
PRINZEN, FW
RENEMAN, RS
机构
[1] UNIV LIMBURG, CARDIOVASC RES INST MAASTRICHT, DEPT PHYSIOL, POB 616, 6200 MD MAASTRICHT, NETHERLANDS
[2] UNIV LIMBURG, CARDIOVASC RES INST MAASTRICHT, DEPT BIOPHYS, 6200 MD MAASTRICHT, NETHERLANDS
来源
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY | 1993年 / 423卷 / 1-2期
关键词
LEFT VENTRICLE; CARDIAC MECHANICS; ELECTRICAL ACTIVATION; FIBER STRAIN;
D O I
10.1007/BF00374964
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
To determine the relation between regional electrical activation time and fiber strain, epicardial electrical activation and deformation were measured in six open-chest dogs at the left ventricular anterior free wall after 15 min of right atrial, left ventricular free wall, left ventricular apex, or right ventricular outflow tract pacing, when end-diastolic pressure was normal or elevated (volume-loading). Regional electrical activation was measured using a 192-electrode brush. Regional subepicardial fiber strain (e(f)) was measured simultaneously in 16 regions, using optical markers which were attached to the epicardial surface and recorded on video. When relating regional e(f) during the ejection phase to regional activation time, the best correlation was found when a hemodynamic time reference rather than an electrophysiological one is used. Using the moment of the maximum rate of change of left ventricular pressure as the time reference for electrical activation, regional electrical activation time (t(ea)) and the degree of e, during the ejection phase could be fitted by a linear regression equation e(f) = a t(ea) + b, in which a = -3.46 +/- 0.73 s-1 and b = -0.28 +/- 0.05. For electrical activation times ranging from - 40 to - 80 ms, fiber strain was estimated with an accuracy of +/- 0.026 (+/- SE) with this relation. During right atrial pacing, t(ea) and e(f) were on the average -48 ms and -0.10 respectively. On further investigation, the relation between e(f) and t(ea) appeared to be influenced by end-diastolic pressure. For normal (1.1 kPa) and elevated end-diastolic pressure (1.8 kPa), the slope of the linear regression line was -3.96 and -2.86 s-1, respectively. Three conclusions may be drawn. Firstly, the time interval between the moment of regional electrical activation and the moment of the maximum rate of change of left ventricular pressure is an index of regional fiber strain. Secondly, it can be concluded from the above equations that electrical asynchrony of more than 30 ms causes non-uniformities in the degree of e(f) of the order of mean e(f) during pacing from the right atrium. Finally, differences in fiber strain during asynchronous electrical activation are less pronounced at larger filling pressures.
引用
收藏
页码:78 / 87
页数:10
相关论文
共 31 条
[1]  
Allessie M A, 1986, Int J Card Imaging, V2, P59, DOI 10.1007/BF01553938
[2]   WALL MOTION ASYNCHRONY PROLONGS TIME CONSTANT OF LEFT-VENTRICULAR RELAXATION [J].
AOYAGI, T ;
IIZUKA, M ;
TAKAHASHI, T ;
OHYA, T ;
SERIZAWA, T ;
MOMOMURA, S ;
SATO, H ;
MOCHIZUKI, T ;
MATSUI, H ;
IKENOUCHI, H ;
SHIN, I ;
MA, YX ;
SUGIMOTO, T .
AMERICAN JOURNAL OF PHYSIOLOGY, 1989, 257 (03) :H883-H890
[3]   EPICARDIAL DEFORMATION AND LEFT-VENTRICULAR WALL MECHANICS DURING EJECTION IN THE DOG [J].
ARTS, T ;
VEENSTRA, PC ;
RENEMAN, RS .
AMERICAN JOURNAL OF PHYSIOLOGY, 1982, 243 (03) :H379-H390
[4]   RELATION BETWEEN LEFT-VENTRICULAR CAVITY PRESSURE AND VOLUME AND SYSTOLIC FIBER STRESS AND STRAIN IN THE WALL [J].
ARTS, T ;
BOVENDEERD, PHM ;
PRINZEN, FW ;
RENEMAN, RS .
BIOPHYSICAL JOURNAL, 1991, 59 (01) :93-102
[5]   MAPPING THE SEQUENCE OF CONTRACTION OF THE CANINE LEFT-VENTRICLE [J].
AUGUSTIJN, CH ;
ARTS, T ;
PRINZEN, FW ;
RENEMAN, RS .
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1991, 419 (05) :529-533
[6]   EFFECTS OF VENTRICULAR PACING ON REGIONAL LEFT-VENTRICULAR PERFORMANCE IN THE DOG [J].
BADKE, FR ;
BOINAY, P ;
COVELL, JW .
AMERICAN JOURNAL OF PHYSIOLOGY, 1980, 238 (06) :H858-H867
[7]   COMPARISON OF THE EFFECTS OF RIGHT ATRIAL, RIGHT VENTRICULAR APEX AND ATRIOVENTRICULAR SEQUENTIAL PACING ON MYOCARDIAL OXYGEN-CONSUMPTION AND CARDIAC EFFICIENCY - A LABORATORY INVESTIGATION [J].
BALLER, D ;
WOLPERS, HG ;
ZIPFEL, J ;
BRETSCHNEIDER, HJ ;
HELLIGE, G .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (04) :394-403
[8]   INFLUENCE OF PACING SITE ON CANINE LEFT-VENTRICULAR CONTRACTION [J].
BURKHOFF, D ;
OIKAWA, RY ;
SAGAWA, K .
AMERICAN JOURNAL OF PHYSIOLOGY, 1986, 251 (02) :H428-H435
[9]   DETERMINATION OF TISSUE MOTION VELOCITY BY CORRELATION INTERPOLATION OF PULSED ULTRASONIC ECHO SIGNALS [J].
DEJONG, PGM ;
ARTS, T ;
HOEKS, APG ;
RENEMAN, RS .
ULTRASONIC IMAGING, 1990, 12 (02) :84-98
[10]   ENDOCARDIAL PACING SITE AFFECTS LEFT-VENTRICULAR END-DIASTOLIC VOLUME AND PERFORMANCE IN THE INTACT ANESTHETIZED DOG [J].
GROVER, M ;
GLANTZ, SA .
CIRCULATION RESEARCH, 1983, 53 (01) :72-85