AXIAL-BEAM ABSORBENCY DETECTION FOR CAPILLARY ELECTROPHORESIS

被引:34
作者
TAYLOR, JA [1 ]
YEUNG, ES [1 ]
机构
[1] IOWA STATE UNIV SCI & TECHNOL,DEPT CHEM,AMES,IA 50011
来源
JOURNAL OF CHROMATOGRAPHY | 1991年 / 550卷 / 1-2期
关键词
D O I
10.1016/S0021-9673(01)88586-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel approach to absorbance detection has been demonstrated for capillary electrophoresis utilizing an incident light beam directed along the capillary axis. The resulting absorption path length is roughly equal to the width of the sample bands present. This represents a 60-fold improvement in analytical path length over conventional on-column absorbance detectors without any loss of separation efficiency. The method can be used with completely aqueous buffer systems or those containing organic modifiers, and is applicable to both fused-silica and PTFE capillaries.
引用
收藏
页码:831 / 837
页数:7
相关论文
共 16 条
[1]   LASER DETECTORS FOR CAPILLARY LIQUID-CHROMATOGRAPHY [J].
DOVICHI, NJ ;
ZARRIN, F ;
NOLAN, TG ;
BORNHOP, DJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1988, 43 (4-5) :639-649
[2]   EFFECT OF ADDITION OF ORGANIC-SOLVENT ON THE SEPARATION OF POSITIONAL ISOMERS IN HIGH-VOLTAGE CAPILLARY ZONE ELECTROPHORESIS [J].
FUJIWARA, S ;
HONDA, S .
ANALYTICAL CHEMISTRY, 1987, 59 (03) :487-490
[3]   COLORIMETRY WITH A TOTAL-REFLECTION LONG CAPILLARY CELL [J].
FUWA, K ;
LEI, W ;
FUJIWARA, K .
ANALYTICAL CHEMISTRY, 1984, 56 (09) :1640-1644
[4]   HIGH-PERFORMANCE ELECTROPHORESIS - ELIMINATION OF ELECTROENDOSMOSIS AND SOLUTE ADSORPTION [J].
HJERTEN, S .
JOURNAL OF CHROMATOGRAPHY, 1985, 347 (02) :191-198
[5]  
HUANG X, 1989, J CHROMATOGR, V480, P101
[6]  
KUHR WG, 1990, ANAL CHEM, V62, pR404
[7]   DETERMINATION OF PHOSPHORUS IN NATURAL-WATERS BY LONG-CAPILLARY-CELL ABSORPTION SPECTROMETRY [J].
LEI, W ;
FUJIWARA, K ;
FUWA, K .
ANALYTICAL CHEMISTRY, 1983, 55 (06) :951-955
[8]   CAPILLARY ZONE ELECTROPHORESIS - EFFECT OF PHYSICAL PARAMETERS ON SEPARATION EFFICIENCY AND QUANTITATION [J].
LUKACS, KD ;
JORGENSON, JW .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1985, 8 (08) :407-411
[9]   EXPERIMENTAL DEVICE FOR ELECTROKINETIC MICELLAR CHROMATOGRAPHY EXPLOITING SOME COMPONENTS OF CAPILLARY ISOTACHOPHORESIS INSTRUMENTATION [J].
PRUSIK, Z ;
KASICKA, V ;
STANEK, S ;
KUNCOVA, G ;
HAYER, M ;
VRKOC, J .
JOURNAL OF CHROMATOGRAPHY, 1987, 390 (01) :87-96
[10]   SMOOTHING + DIFFERENTIATION OF DATA BY SIMPLIFIED LEAST SQUARES PROCEDURES [J].
SAVITZKY, A ;
GOLAY, MJE .
ANALYTICAL CHEMISTRY, 1964, 36 (08) :1627-&