MECHANISMS OF RESTENOSIS AND REDILATION WITHIN CORONARY STENTS - QUANTITATIVE ANGIOGRAPHIC ASSESSMENT

被引:208
作者
GORDON, PC
GIBSON, CM
COHEN, DJ
CARROZZA, JP
KUNTZ, RE
BAIM, DS
机构
[1] BETH ISRAEL HOSP, DEPT MED, DIV CARDIOVASC, HARVARD THORNDIKE LAB, BOSTON, MA 02215 USA
[2] CHARLES A DANA RES INST, BOSTON, MA USA
[3] HARVARD UNIV, SCH MED, BOSTON, MA 02115 USA
关键词
D O I
10.1016/0735-1097(93)90241-R
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. This study was designed to assess the relative contributions of intimal hyperplasia and stent compression to the lumen narrowing seen after intracoronary stenting and to determine whether the lumen enlargement produced by angioplasty of in-stent restenosis results primarily from compression or extrusion of intimal hyperplasia through the stent or from additional stent expansion. Background. Palmaz-Schatz stent placement outwardly displaces plaque and eliminates elastic vessel recoil to provide a large and smooth lumen. Some degree of late lumen narrowing occurs within each stent and causes significant restenosis (greater-than-or-equal-to 50% stenosis) in 25% to 30% of treated lesions. It has not been clear, however, whether this narrowing results from stent compression (crush) or from in-stent intimal hyperplasia. Because the Palmaz-Schatz stent has a distinct radiographic shadow, it is possible to determine the late diameter of both the stent and the enclosed vessel lumen to assess the relative contributions of these two processes. Methods. From cineangiograms, initial (after stenting) and late (follow-up) lumen and stent diameters were examined in 55 patients (59 stents, group I) who had both immediate and 6-month (192 +/- 117 days) angiography. Lumen and stent diameter were also examined before and after dilation in 30 patients (30 stents, group II) who underwent angioplasty of severe in-stent restenosis. Results. Late loss in minimal lumen diameter was 0.99 +/-0.87 mm for group I despite only a slight (0.03 +/- 0.23-mm) reduction in the corresponding stent diameter. After redilation for in-stent restenosis, the acute gain in minimal lumen diameter was 1.51 +/- 0.82 mm for group II, again without appreciable increase (0.06 +/- 0.20 mm) in stent diameter. Conclusions. Restenosis after intracoronary Palmaz-Schatz stenting appears to be due predominantly to lumen encroachment by intimal hyperplasia within the stent, with minimal contribution of stent compression. Lumen enlargement after coronary angioplasty of in-stent restenosis appears to be due primarily to compression or extrusion of intimal hyperplasia through the stent, or both, rather than to further stent expansion.
引用
收藏
页码:1166 / 1174
页数:9
相关论文
共 36 条
  • [1] MANAGEMENT OF RESTENOSIS WITHIN THE PALMAZ-SCHATZ CORONARY STENT (THE UNITED-STATES MULTICENTER EXPERIENCE)
    BAIM, DS
    LEVINE, MJ
    LEON, MB
    LEVINE, S
    ELLIS, SG
    SCHATZ, RA
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (04) : 364 - 366
  • [2] BONNER RF, 1991, CIRCULATION S2, V84, P197
  • [3] QUANTITATIVE CORONARY ARTERIOGRAPHY - ESTIMATION OF DIMENSIONS, HEMODYNAMIC RESISTANCE, AND ATHEROMA MASS OF CORONARY-ARTERY LESIONS USING ARTERIOGRAM AND DIGITAL COMPUTATION
    BROWN, BG
    BOLSON, E
    FRIMER, M
    DODGE, HT
    [J]. CIRCULATION, 1977, 55 (02) : 329 - 337
  • [4] ANGIOGRAPHIC AND CLINICAL OUTCOME OF INTRACORONARY STENTING - IMMEDIATE AND LONG-TERM RESULTS FROM A LARGE SINGLE-CENTER EXPERIENCE
    CARROZZA, JP
    KUNTZ, RE
    LEVINE, MJ
    POMERANTZ, RM
    FISHMAN, RF
    MANSOUR, M
    GIBSON, CM
    SENERCHIA, CC
    DIVER, DJ
    SAFIAN, RD
    BAIM, DS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (02) : 328 - 337
  • [5] WIKTOR STENT IMPLANTATION IN PATIENTS WITH RESTENOSIS FOLLOWING BALLOON ANGIOPLASTY OF A NATIVE CORONARY-ARTERY
    DEJAEGERE, PP
    SERRUYS, PW
    BERTRAND, M
    WIEGAND, V
    KOBER, G
    MARQUIS, JF
    VALEIX, B
    UEBIS, R
    PIESSENS, J
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (06) : 598 - 602
  • [6] PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY IN 1985-1986 AND 1977-1981 - THE NATIONAL-HEART-LUNG-AND-BLOOD-INSTITUTE REGISTRY
    DETRE, K
    HOLUBKOV, R
    KELSEY, S
    COWLEY, M
    KENT, K
    WILLIAMS, D
    MYLER, R
    FAXON, D
    HOLMES, D
    BOURASSA, M
    BLOCK, P
    GOSSELIN, A
    BENTIVOGLIO, L
    LEATHERMAN, L
    DORROS, G
    KING, S
    GALICHIA, J
    ALBASSAM, M
    LEON, M
    ROBERTSON, T
    PASSAMANI, E
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1988, 318 (05) : 265 - 270
  • [7] RESTENOSIS AFTER PLACEMENT OF PALMAZ-SCHATZ STENTS IN NATIVE CORONARY-ARTERIES - INITIAL RESULTS OF A MULTICENTER EXPERIENCE
    ELLIS, SG
    SAVAGE, M
    FISCHMAN, D
    BAIM, DS
    LEON, M
    GOLDBERG, S
    HIRSHFELD, JW
    CLEMAN, MW
    TEIRSTEIN, PS
    WALKER, C
    BAILEY, S
    BUCHBINDER, M
    TOPOL, EJ
    SCHATZ, RA
    [J]. CIRCULATION, 1992, 86 (06) : 1836 - 1844
  • [8] PITFALLS IN THE DETERMINATION OF ABSOLUTE DIMENSIONS USING ANGIOGRAPHIC CATHETERS AS CALIBRATION DEVICES IN QUANTITATIVE ANGIOGRAPHY
    FORTIN, DF
    SPERO, LA
    CUSMA, JT
    SANTORO, L
    BURGESS, R
    BASHORE, TM
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (11) : 1176 - 1182
  • [9] QUANTITATIVE ANGIOGRAPHIC AND STATISTICAL-METHODS TO ASSESS SERIAL CHANGES IN CORONARY LUMINAL DIAMETER AND IMPLICATIONS FOR ATHEROSCLEROSIS REGRESSION TRIALS
    GIBSON, M
    SANDOR, T
    STONE, PH
    PASTERNAK, RC
    ROSNER, B
    SACKS, FM
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (16) : 1286 - 1290
  • [10] LONG-TERM FOLLOW-UP AFTER PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY - THE EARLY ZURICH EXPERIENCE
    GRUENTZIG, AR
    KING, SB
    SCHLUMPF, M
    SIEGENTHALER, W
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1987, 316 (18) : 1127 - 1132