HEPATIC AMINO-NITROGEN CLEARANCE TO UREA-NITROGEN IN CONTROL SUBJECTS AND IN PATIENTS WITH CIRRHOSIS - A SIMPLIFIED METHOD

被引:33
作者
BIANCHI, G
MARCHESINI, G
VILSTRUP, H
FABBRI, A
DEMITRI, MS
ZOLI, M
PISI, E
机构
[1] UNIV BOLOGNA,POLICLIN S ORSOLA,IST CLIN MED GEN & TERAPIA MED,9 VIA MASSARENTI,I-40138 BOLOGNA,ITALY
[2] RIGSHOSP,DIV HEPATOL,COPENHAGEN,DENMARK
关键词
D O I
10.1002/hep.1840130313
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
The functional hepatic nitrogen clearance during amino acid infusion is a measure of liver cell mass. The clinical feasibility of the test has so far been limited by methodological problems. A simplified procedure was used to measure the urea-nitrogen synthesis rate and functional hepatic nitrogen clearance in nine subjects with normal liver function and in nine patients with cirrhosis. The method was based on only four consecutive 2-hr urine collections and five blood samples. Total body water was calculated from a nomogram based on age and anthropometric data, whereas the gut urea hydrolysis was assigned one fixed fraction of synthesis (0.17 in control subjects and 0.26 in patients with cirrhosis). Finally, a solution of a single amino acid, alanine, was infused as substrate for urea synthesis. Urea-nitrogen synthesis rate increased linearly with increasing alpha-amino-nitrogen concentration, and the slope of the regression (functional hepatic nitrogen clearance) was reduced in cirrhosis from 37.5 +/- 7.0 L/hr to 18.4 +/- 6.7 L/hr; p < 0.005. The hepatic nitrogen clearance was linearly related to the clinical status (Child-Pugh score), to routine liver function tests and to galactose elimination capacity (r = 0.869), a well-established, quantitative, liver function measure. The simplified method makes the measurement of hepatic nitrogen clearance suitable for routine clinical use. The test might prove useful to study the alterations of nitrogen metabolism in cirrhosis, with special reference to hepatic encephalopathy.
引用
收藏
页码:460 / 466
页数:7
相关论文
共 31 条
[1]   LOSS OF NITROGEN FROM ORGANS IN RATS INDUCED BY EXOGENOUS GLUCAGON [J].
ALMDAL, TP ;
VILSTRUP, H .
ENDOCRINOLOGY, 1988, 123 (05) :2182-2186
[2]  
CLOWES GHA, 1984, SURGERY, V96, P675
[3]  
COLTON T, 1974, STATISTICS MED
[4]   A SIMPLE METHOD FOR DETERMINATION OF ANTIPYRINE CLEARANCE [J].
DOSSING, M ;
POULSEN, HE ;
ANDREASEN, PB ;
TYGSTRUP, N .
CLINICAL PHARMACOLOGY & THERAPEUTICS, 1982, 32 (03) :392-396
[5]   MULTIPLE RANGE TESTS FOR CORRELATED AND HETEROSCEDASTIC MEANS [J].
DUNCAN, DB .
BIOMETRICS, 1957, 13 (02) :164-176
[6]   RELATIONSHIP BETWEEN THE BASAL BLOOD ALANINE CONCENTRATION AND THE REMOVAL OF AN ALANINE LOAD IN VARIOUS CLINICAL STATES IN MAN [J].
ELIA, M ;
ILIC, V ;
BACON, S ;
WILLIAMSON, DH ;
SMITH, R .
CLINICAL SCIENCE, 1980, 58 (04) :301-309
[7]   A RAPID AND PRECISE METHOD FOR THE DETERMINATION OF UREA [J].
FAWCETT, JK ;
SCOTT, JE .
JOURNAL OF CLINICAL PATHOLOGY, 1960, 13 (02) :156-159
[9]   DETERMINATION OF THE RATE OF UREA SYNTHESIS FROM SERIAL MEASUREMENTS OF PLASMA UREA CONCENTRATION AFTER AN ALANINE LOAD - THEORETICAL AND METHODOLOGICAL ASPECTS [J].
GEISELER, D ;
KAY, JDS ;
OBERHOLZER, VG ;
SEAKINS, JWT ;
HJELM, M .
CLINICAL SCIENCE, 1985, 68 (02) :201-208
[10]  
Goodwin JF, 1970, STAND METHODS CLIN C, V6, P89, DOI [10.1016/B978-0-12-609106-9.50014-2, DOI 10.1016/B978-0-12-609106-9.50014-2]