CLINICAL COMPARISON OF THE ISOLATOR AND BACT/ALERT AEROBIC BLOOD CULTURE SYSTEMS

被引:25
作者
HELLINGER, WC
CAWLEY, JJ
ALVAREZ, S
HOGAN, SF
HARMSEN, WS
ILSTRUP, DM
COCKERILL, FR
机构
[1] MAYO CLIN JACKSONVILLE, DEPT PATHOL, JACKSONVILLE, FL 32224 USA
[2] MAYO CLIN & MAYO FDN, DEPT HLTH SCI RES, BIOSTAT SECT, ROCHESTER, MN 55905 USA
[3] MAYO CLIN & MAYO FDN, DEPT LAB MED & PATHOL, DIV CLIN MICROBIOL, ROCHESTER, MN 55905 USA
[4] MAYO CLIN & MAYO FDN, DEPT INTERNAL MED, DIV INFECT DIS, ROCHESTER, MN 55905 USA
关键词
D O I
10.1128/JCM.33.7.1787-1790.1995
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The performance characteristics of the Isolator (Wampole Laboratories, Cranbury, N,J.) and the BacT/Alert (Organon Teknika Corporation, Durham, N.C.) aerobic blood culture systems were compared for 6,009 blood culture sets obtained from patients with suspected bloodstream infections. The BacT/Alert aerobic bottle [BTA(O-2)] was continuously agitated while it was incubated in 5% CO2 at 36 degrees C; culture plates prepared from the Isolator tube [I(O-2)] were incubated in 5% CO2 at 37 degrees C. From 394 blood cultures, 416 clinically significant isolates of bacteria and yeasts were recovered. The overall yields for BTA(O-2) and I(O-2) were not significantly different (319 versus 336; P = 0.20). I(O-2) recovered significantly more staphylococcus (P < 0.05) and yeast isolates (P < 0.01). BTA(O-2) recovered significantly more aerobic and facultatively anaerobic gram-negative bacilli (P < 0.05), In blood culture sets which produced growth of the same organisms in both the BTA(O-2) and I(O-2) systems, the BTA(O-2) system detected growth sooner, but more rapid identification was possible with the I(O-2) system by virtue of earlier isolation of colonies on solid media.
引用
收藏
页码:1787 / 1790
页数:4
相关论文
共 8 条
[1]   COMPARISON OF LYSIS-CENTRIFUGATION WITH A BIPHASIC BLOOD CULTURE-MEDIUM FOR THE RECOVERY OF AEROBIC AND FACULTATIVELY ANAEROBIC-BACTERIA [J].
HENRY, NK ;
GREWELL, CM ;
VANGREVENHOF, PE ;
ILSTRUP, DM ;
WASHINGTON, JA .
JOURNAL OF CLINICAL MICROBIOLOGY, 1984, 20 (03) :413-416
[2]   CLINICAL COMPARISON OF ISOLATOR AND THIOL BROTH WITH ESP AEROBIC AND ANAEROBIC BOTTLES FOR RECOVERY OF PATHOGENS FROM BLOOD [J].
KELLOGG, JA ;
BANKERT, DA ;
MANZELLA, JP ;
PARSEY, KS ;
SCOTT, SL ;
CAVANAUGH, SH .
JOURNAL OF CLINICAL MICROBIOLOGY, 1994, 32 (09) :2050-2055
[3]   CONTROLLED CLINICAL COMPARISON OF 2 LYSIS-BASED BLOOD CULTURE SYSTEMS, ISOLATOR AND SEPTI-CHEK RELEASE, FOR DETECTION OF BLOOD-STREAM INFECTIONS [J].
KIRKLEY, BA ;
EASLEY, KA ;
BASILLE, BA ;
WASHINGTON, JA .
JOURNAL OF CLINICAL MICROBIOLOGY, 1993, 31 (08) :2114-2117
[4]   CONTROLLED CLINICAL-EVALUATION OF ISOLATOR AND ESP AEROBIC BLOOD CULTURE SYSTEMS FOR DETECTION OF BLOOD-STREAM INFECTIONS [J].
KIRKLEY, BA ;
EASLEY, KA ;
WASHINGTON, JA .
JOURNAL OF CLINICAL MICROBIOLOGY, 1994, 32 (06) :1547-1549
[5]  
QUON T, 1991, 61ST GEN M AM SOC MI, P402
[6]  
WILCOXON F, 1946, J ECON ENTOMOL, V39, P269, DOI 10.1093/jee/39.2.269
[7]   CONTROLLED COMPARISON OF THE BACT ALERT AND BACTEC-660/730 NONRADIOMETRIC BLOOD CULTURE SYSTEMS [J].
WILSON, ML ;
WEINSTEIN, MP ;
REIMER, LG ;
MIRRETT, S ;
RELLER, LB .
JOURNAL OF CLINICAL MICROBIOLOGY, 1992, 30 (02) :323-329
[8]   COMPARISON OF DIFCO ESP AND ORGANON-TEKNIKA BACT/ALERT CONTINUOUS-MONITORING BLOOD CULTURE SYSTEMS [J].
ZWADYK, P ;
PIERSON, CL ;
YOUNG, C .
JOURNAL OF CLINICAL MICROBIOLOGY, 1994, 32 (05) :1273-1279