DIRECT EFFECTS OF PROPOFOL ON MYOCARDIAL-CONTRACTILITY IN INSITU CANINE HEARTS

被引:56
作者
ISMAIL, EF
KIM, SJ
SALEM, MR
CRYSTAL, GJ
机构
[1] ILLINOIS MASONIC MED CTR,DEPT ANESTHESIOL,836 W WELLINGTON AVE,CHICAGO,IL 60657
[2] UNIV ILLINOIS,COLL MED,DEPT ANESTHESIOL,CHICAGO,IL 60680
[3] UNIV ILLINOIS,COLL MED,DEPT BIOPHYS,CHICAGO,IL 60680
关键词
ANESTHETICS; INTRAVENOUS; PROPOFOL; HEART; CORONARY BLOOD FLOW; MYOCARDIAL CONTRACTILITY; MYOCARDIAL OXYGEN CONSUMPTION;
D O I
10.1097/00000542-199211000-00020
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The pronounced decrease in arterial blood pressure evident during anesthetic induction with propofol has raised the possibility that propofol has a direct negative inotropic effect. Previous attempts to evaluate this mechanism in vivo have been inconclusive because of confounding variables associated with intravenous administration of propofol. Accordingly, in the current study, steady-state changes in myocardial contractility and related hemodynamic parameters were assessed during intracoronary infusions of propofol in seven open-chest dogs anesthetized with fentanyl and midazolam. The left anterior descending coronary artery (LAD) was cannulated and perfused at controlled pressure (100 mmHg) with normal arterial blood. In LAD-perfused myocardium, contractility was evaluated from measurements of percent segmental shortening (%SS) obtained with ultrasonic crystals. Coronary blood flow in LAD was measured electromagnetically and used to calculate myocardial oxygen consumption (MV(O2); Fick principle) and coronary propofol concentration. Propofol was infused into the LAD at 150, 300, 600, and 1,200 mug/min (P-150, P-300, P-600, P-1,200). These infusion rates yielded calculated blood concentrations of 7 +/- 1, 15 +/- 1, 26 +/- 2, and 50 +/- 5 mug.ml-1, respectively. The calculated blood concentrations at P-150 were in the clinical range, whereas those at P-300, P-600, and P-1,200 were supratherapeutic. P-150 had no effect on %SS, whereas higher infusion rates caused decreases in %SS. Changes in MV(O2) by propofol generally paralleled changes in %SS. At P-150 and P-300, coronary blood flow was proportional to MV(O2), whereas at P-600 and P-1,200, coronary blood flow was in excess of the prevailing MV(O2), resulting in increased coronary venous oxygen tension. In conclusion, propofol at clinically relevant blood concentrations has no direct negative inotropic effect in the in situ canine heart, although at supratherapeutic concentrations it causes cardiac depression.
引用
收藏
页码:964 / 972
页数:9
相关论文
共 34 条
[1]  
BARON J F, 1990, Anesthesiology (Hagerstown), V73, pA561
[2]  
BERENS R J, 1990, Anesthesiology (Hagerstown), V73, pA343
[3]  
BRAUNWALD E, 1979, HDB PHYSL 2, V1, P544
[4]  
BRUSSEL T, 1989, ANESTH ANALG, V69, P35
[5]   SOME SOURCES OF ERROR IN MEASURING REGIONAL BLOOD FLOW WITH RADIOACTIVE MICROSPHERES [J].
BUCKBERG, GD ;
LUCK, JC ;
PAYNE, DB ;
HOFFMAN, JIE ;
ARCHIE, JP ;
FIXLER, DE .
JOURNAL OF APPLIED PHYSIOLOGY, 1971, 31 (04) :598-&
[6]  
COATES DP, 1987, ANESTH ANALG, V66, P64
[7]  
COETZEE A, 1989, ANESTH ANALG, V69, P473
[8]   INTRACORONARY ISOFLURANE CAUSES MARKED VASODILATION IN CANINE HEARTS [J].
CRYSTAL, GJ ;
KIM, SJ ;
CZINN, EA ;
SALEM, MR ;
MASON, WR ;
ABDELLATIF, M .
ANESTHESIOLOGY, 1991, 74 (04) :757-765
[9]   SMALL VESSEL AND TOTAL CORONARY BLOOD-VOLUME DURING INTRA-CORONARY ADENOSINE [J].
CRYSTAL, GJ ;
DOWNEY, HF ;
BASHOUR, FA .
AMERICAN JOURNAL OF PHYSIOLOGY, 1981, 241 (02) :H194-H201
[10]  
CRYSTAL GJ, 1988, ANESTH ANALG, V67, P500