TENDONS ATTACHED TO PROSTHESES BY TENDON BONE BLOCK FIXATION - AN EXPERIMENTAL-STUDY IN DOGS

被引:39
作者
GOTTSAUNERWOLF, F [1 ]
EGGER, EL [1 ]
SCHULTZ, FM [1 ]
SIM, FH [1 ]
CHAO, EYS [1 ]
机构
[1] MAYO CLIN & MAYO FDN,DEPT ORTHOPED,BIOMECH LAB,ROCHESTER,MN 55905
关键词
D O I
10.1002/jor.1100120609
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
To develop a method of tendon attachment to a metallic endoprosthesis, we evaluated fixation strength, clinical function of the tendon, and morphological changes in an experimental model. The canine supraspinatus tendon was removed from the greater tubercle of the humerus and attached to a titanium prosthesis. In 12 animals, the bone block underlying the tendon insertion was preserved and attached in one limb; the soft part of the tendon was attached directly to the prosthesis in the contralateral limb. Fixation strength was evaluated after 16 weeks of in vivo implantation (12 specimens) and compared with the in vitro fixation strength (12 specimens) and with intact normal controls (six specimens from cadavera). Function of the tendon in vivo was evaluated by force-plate analysis (at 3-week intervals). All specimens were evaluated histologically. Sixteen weeks after surgery, the tendon-bone block attachment was significantly stronger (mean, 16%) than the direct tendon attachment and not significantly different from the normal control, and the direct tendon attachment was significantly weaker (mean, 68%) than the normal control. There was significantly more weight-bearing on the limbs with a tendon-bone block attachment than on the limbs with a direct tendon attachment at bath 3 and 6 weeks postoperatively. Both front legs showed increased weight-bearing with time, but the differences were not statistically significant. Anchorage by tissue ingrowth to the titanium prosthesis was found consistently - there was bone ingrowth in the tendon-bone block attachments and fibrous tissue ingrowth in the direct tendon attachments. When a bane block was preserved, the strength and stiffness were comparable with those of a normal tendon insertion. This mechanical linkage was capable of transmitting muscle forces to the prosthesis and consequently to the limb.
引用
收藏
页码:814 / 821
页数:8
相关论文
共 28 条
[1]   ANTERIOR CRUCIATE LIGAMENT REPLACEMENT USING PATELLAR TENDON - AN EVALUATION OF GRAFT REVASCULARIZATION IN THE DOG [J].
ARNOCZKY, SP ;
TARVIN, GB ;
MARSHALL, JL .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (02) :217-224
[2]  
Bobyn J.D., 1980, CLIN ORTHOP RELAT R, V149, P291
[3]   EFFECT OF PORE-SIZE ON THE PEEL STRENGTH OF ATTACHMENT OF FIBROUS TISSUE TO POROUS-SURFACED IMPLANTS [J].
BOBYN, JD ;
WILSON, GJ ;
MACGREGOR, DC ;
PILLIAR, RM ;
WEATHERLY, GC .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1982, 16 (05) :571-584
[4]  
BOBYN JD, 1980, CLIN ORTHOPAEDICS, V150, P263
[5]  
BOS G, 1987, BRISTOL MEYERS ZIMME, P61
[6]  
CHAO EYS, 1985, ORTHOPEDICS, V8, P641
[7]   ANTERIOR AND POSTERIOR CRUCIATE LIGAMENT RECONSTRUCTION IN RHESUS-MONKEYS - A HISTOLOGICAL, MICRO-ANGIOGRAPHIC, AND BIOMECHANICAL ANALYSIS [J].
CLANCY, WG ;
NARECHANIA, RG ;
ROSENBERG, TD ;
GMEINER, JG ;
WISNEFSKE, DD ;
LANGE, TA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1981, 63 (08) :1270-1284
[8]  
DUCHEYNE P, 1977, J BIOMED MATER RES, V11, P811, DOI 10.1002/jbm.820110603
[9]   BIOMECHANICAL EVALUATION OF ROTATOR CUFF FIXATION METHODS [J].
FRANCE, EP ;
PAULOS, LE ;
HARNER, CD ;
STRAIGHT, CB .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1989, 17 (02) :176-181
[10]  
FRASSICA FJ, 1987, AM SURGEON, V53, P264