HISTOLOGICAL AND HISTOMORPHOMETRICAL EVALUATION OF THE BONE REACTION TO 3 DIFFERENT TITANIUM-ALLOY AND HYDROXYAPATITE-COATED IMPLANTS

被引:27
作者
JANSEN, JA [1 ]
VANDERWAERDEN, JPCM [1 ]
WOLKE, JGC [1 ]
机构
[1] LEIDEN UNIV,SCH MED,DEPT BIOMAT,2300 RA LEIDEN,NETHERLANDS
关键词
D O I
10.1002/jab.770040302
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
The aim of this study was to investigate the bone response to three different types of titanium (Ti) alloys and hydroxyapatite (HA) coated titanium alloy by histological and histomorphometrical analysis. Therefore, implants made of these materials were inserted into the tibia of rabbits. Implantation times were 6 and 16 weeks. The histological evaluation included measurement of the amount of bone apposition and analysis of the bone reaction and interface characteristics around the implants. The results demonstrated no marked differences in bony reaction to the different implant materials. In addition, the HA coatings showed loss of thickness. (C) 1993 John Wiley & Sons, Inc.
引用
收藏
页码:213 / 219
页数:7
相关论文
共 24 条
[1]
BONE-METAL INTERFACE IN OSSEOINTEGRATION [J].
ALBREKTSSON, T ;
JACOBSSON, M .
JOURNAL OF PROSTHETIC DENTISTRY, 1987, 57 (05) :597-607
[2]
METALLOSIS ASSOCIATED WITH A STABLE TITANIUM-ALLOY FEMORAL COMPONENT IN TOTAL HIP-REPLACEMENT - A CASE-REPORT [J].
BLACK, J ;
SHERK, H ;
BONINI, J ;
ROSTOKER, WR ;
SCHAJOWICZ, F ;
GALANTE, JO .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (01) :126-130
[3]
BREME J, 1990, OSSEO INTEGRATED IMP, V1, P31
[4]
Campbell C E, 1989, J Invest Surg, V2, P51, DOI 10.3109/08941938909016503
[5]
PLASMA SPRAYED COATINGS OF HYDROXYLAPATITE [J].
DEGROOT, K ;
GEESINK, R ;
KLEIN, CPAT ;
SEREKIAN, P .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1987, 21 (12) :1375-1381
[6]
INTERFACE BETWEEN BONE TISSUE AND IMPLANTS OF SOLID HYDROXYAPATITE OR HYDROXYAPATITE-COATED TITANIUM IMPLANTS [J].
DELANGE, GL ;
DONATH, K .
BIOMATERIALS, 1989, 10 (02) :121-125
[7]
THE BIOLOGIC EFFECTS OF IMPLANT MATERIALS [J].
GALANTE, JO ;
LEMONS, J ;
SPECTOR, M ;
WILSON, PD ;
WRIGHT, TM .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (05) :760-775
[8]
HANAWA T, 1991, BONE BIOMATERIAL INT, P47
[9]
THE EFFECTS OF MECHANICAL FACTORS ON BIO-COMPATIBILITY TESTS [J].
HEIMKE, G ;
GRISS, P ;
WERNER, E ;
JENTSCHURA, G .
JOURNAL OF BIOMEDICAL ENGINEERING, 1981, 3 (03) :209-213
[10]
RELEASE AND EXCRETION OF METAL IN PATIENTS WHO HAVE A TOTAL HIP-REPLACEMENT COMPONENT MADE OF TITANIUM-BASE ALLOY [J].
JACOBS, JJ ;
SKIPOR, AK ;
BLACK, J ;
URBAN, RM ;
GALANTE, JO .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (10) :1475-1486