SPECTROPHOTOMETRIC DETERMINATION OF CALCIUM WITH DICYCLOHEXANO-24-CROWN-8 AND PROPYL ORANGE BY SOLVENT-EXTRACTION FLOW-INJECTION METHOD

被引:12
作者
MOTOMIZU, S [1 ]
OSHIMA, M [1 ]
YONEDA, N [1 ]
IWACHIDO, T [1 ]
机构
[1] OKAYAMA UNIV, COLL LIBERAL ARTS, OKAYAMA 700, JAPAN
关键词
Calcium; dicyclohexano-24-crown-8; flow-injection method; Propyl Orange; solvent extraction; spectrophotometry;
D O I
10.2116/analsci.6.215
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Calcium in water was determined by a spectrophotometric method involving flow injection coupled with solvent extraction. An ion association complex which formed between a calcium-crown complex ion and a dye anion was extracted into an organic solvent and the absorbance of the organic phase was measured after phase separation. Six derivatives of alkylaminophenylazobenzene sulfonic acid and tetrabromophenolphthalein ethylester were examined as counter anions with dicyclohexano-24-crown-8, and a mixture of benzene and chlorobenzene was examined as an extraction solvent. A suitable method for calcium determination in water was one with Propyl Orange and a (1+1 v/v) mixture of benzene and chlorobenzene. The carrier stream was distilled water, while the reagent stream was comprised of a dye anion and lithium hydroxide. The sampling rate was 20-30 per hour. The calibration graph was linear at concentrations up to 10-4 M using samples of 100 μl. The detection limit corresponding to a signal-to-noise ratio of 3 was 2×10-7 M; the relative standard deviation was 0.99% for 10 injections of 5×10-3 M calcium solution. Calcium in river water was determined satisfactorily by the proposed method. © 1990, The Japan Society for Analytical Chemistry. All rights reserved.
引用
收藏
页码:215 / 220
页数:6
相关论文
共 14 条
[1]   USE OF NON-SEGMENTED HIGH-SPEED CONTINUOUS-FLOW ANALYSIS FOR DETERMINATION OF CALCIUM IN ANIMAL FEEDS [J].
BASSON, WD ;
VANSTADEN, JF .
ANALYST, 1978, 103 (1224) :296-299
[2]  
FIESER LF, 1957, EXPT ORGANIC CHEM
[3]   FLOW INJECTION ANALYSIS FOR CALCIUM IN SERUM, WATER AND WASTE-WATERS BY SPECTROPHOTOMETRY AND BY ION-SELECTIVE ELECTRODE [J].
HANSEN, EH ;
RUZICKA, J ;
GHOSE, AK .
ANALYTICA CHIMICA ACTA, 1978, 100 (SEP) :151-165
[4]  
IWACHIDO T, 1985, BUNSEKI KAGAKU, V34, P579
[5]   MERGING ZONES IN FLOW-INJECTION ANALYSIS .6. DETERMINATION OF CALCIUM IN NATURAL-WATERS, SOIL AND PLANT MATERIALS WITH GLYOXAL BIS(2-HYDROXYANIL) [J].
JACINTHO, AO ;
ZAGATTO, EAG ;
REIS, BF ;
PESSENDA, LCR ;
KRUG, FJ .
ANALYTICA CHIMICA ACTA, 1981, 130 (02) :361-368
[6]   KINETIC DETERMINATION OF MAGNESIUM AND CALCIUM BY STOPPED-FLOW INJECTION-ANALYSIS [J].
KAGENOW, H ;
JENSEN, A .
ANALYTICA CHIMICA ACTA, 1983, 145 (JAN) :125-133
[7]   SPECTROPHOTOMETRIC DETERMINATION OF POTASSIUM IN RIVER WATER BASED ON SOLVENT-EXTRACTION OF THE COMPLEX FORMED WITH A CROWN ETHER AND AN ANIONIC AZO DYE USING FLOW-INJECTION [J].
MOTOMIZU, S ;
ONODA, M ;
OSHIMA, M ;
IWACHIDO, T .
ANALYST, 1988, 113 (05) :743-746
[8]   SPECTROPHOTOMETRIC DETERMINATION OF PHOSPHORUS AS ORTHO-PHOSPHATE BASED ON SOLVENT-EXTRACTION OF THE ION ASSOCIATE OF MOLYBDOPHOSPHATE WITH MALACHITE GREEN USING FLOW-INJECTION [J].
MOTOMIZU, S ;
OSHIMA, M .
ANALYST, 1987, 112 (03) :295-300
[9]  
MOTOMIZU S, 1989, BUNSEKI KAGAKU, V38, P147
[10]   SPECTROPHOTOMETRIC DETERMINATION OF CALCIUM WITH A FLOW-INJECTION SYSTEM [J].
NAKAGAWA, G ;
WADA, H ;
WEI, C .
ANALYTICA CHIMICA ACTA, 1983, 145 (JAN) :135-141