PARALLEL-MODE EXTENDED-PERIOD QUASI-RESONANT CONVERTER

被引:34
作者
CHENG, KWE
EVANS, PD
机构
[1] School of Electronic and Electrical Engineering, University of Birmingham
来源
IEE PROCEEDINGS-B ELECTRIC POWER APPLICATIONS | 1991年 / 138卷 / 05期
关键词
CONVERTERS; POWER ELECTRONICS; RESONANT CONVERTERS; SWITCHED-MODE POWER SUPPLIES;
D O I
10.1049/ip-b.1991.0029
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new circuit, a parallel-mode, extended-period, zero-current quasiresonant convertor (PM-EP-ZCQRC), is introduced. It has low switching losses, because the switching conditions are those of a quasiresonant convertor, but it operates at constant frequency by using the duty-ratio technique of conventional switched-mode power supplies for output regulation. The modes of operation of the circuit are described and analysed. The results of open-loop tests on a prototype circuit are presented and are shown to agree with predictions. The efficiency of the circuit was found to be 80 to 90% and a comparison of loss components with those in a quasiresonant convertor (QRC) is given.
引用
收藏
页码:243 / 251
页数:9
相关论文
共 6 条
[1]  
BARBI I, 1989, IEEE POWER ELECTRONI, P873
[2]  
CHENG KWE, 1990, THESIS U BATH BATH
[3]  
Liu K., 1985, IEEE POWER ELECTRONI, P106
[4]  
LIU KK, 1986, IEEE POWER ELECTRONI, P528
[5]  
ROUFBERG L, 1986, EFFECTS PARASITIC LO, P10
[6]   COMPARISON OF HALF-BRIDGE RESONANT CONVERTER TOPOLOGIES. [J].
Steigerwald, Robert L. .