IDENTIFICATION OF LOWER ARM MOTIONS USING THE EMG SIGNALS OF SHOULDER MUSCLES

被引:23
作者
LATWESEN, A [1 ]
PATTERSON, PE [1 ]
机构
[1] IOWA STATE UNIV, COLL ENGN, DEPT IND & MFG SYST ENGN, AMES, IA 50011 USA
关键词
EMG; MYOELECTRIC CONTROL;
D O I
10.1016/1350-4533(94)90024-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This investigation explored pattern recognition of EMG signals produced by shoulder area muscles to identify the performance of a select number of lower arm motions. The signals were modelled as fourth-order autoregressive processes with the parameters of the models used to classify the different motions. The recorded EMG signal was bandpass filtered for each individual to improve discrimination between signals. The method was shown to detect and identify EMG signatures produced by at least two, and sometimes three, different arm motions. Discrimination between the signal models for the motions was not affected by load variation or muscle fatigue.
引用
收藏
页码:113 / 121
页数:9
相关论文
共 15 条
[1]  
[Anonymous], 1988, MODERN SPECTRAL ESTI
[2]  
[Anonymous], 1977, SYSTEM IDENTIFICATIO
[3]   SIGNAL-PROCESSING FOR PROPORTIONAL MYOELECTRIC CONTROL [J].
EVANS, HB ;
PAN, Z ;
PARKER, PA ;
SCOTT, RN .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1984, 31 (02) :207-211
[4]  
Goodwin GC, 1984, ADAPTIVE FILTERING P
[5]   FUNCTIONAL SEPARATION OF EMG SIGNALS VIA ARMA IDENTIFICATION METHODS FOR PROSTHESIS CONTROL PURPOSES [J].
GRAUPE, D ;
CLINE, WK .
IEEE TRANSACTIONS ON SYSTEMS MAN AND CYBERNETICS, 1975, SMC5 (02) :252-259
[6]  
Graupe D., 1979, Proceedings of the 1979 Joint Automatic Control Conference, P426
[7]  
GRAUPE D, 1972, IDENTIFICATION SYSTE
[8]   THE ELECTROMYOGRAM (EMG) AS A CONTROL SIGNAL FOR FUNCTIONAL NEUROMUSCULAR STIMULATION .1. AUTOREGRESSIVE MODELING AS A MEANS OF EMG SIGNATURE DISCRIMINATION [J].
HEFFTNER, G ;
ZUCCHINI, W ;
JAROS, GG .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (04) :230-238
[9]   THE ELECTROMYOGRAM (EMG) AS A CONTROL SIGNAL FOR FUNCTIONAL NEUROMUSCULAR STIMULATION .2. PRACTICAL DEMONSTRATION OF THE EMG SIGNATURE DISCRIMINATION SYSTEM [J].
HEFFTNER, G ;
JAROS, GG .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (04) :238-242
[10]  
HOGAN N, 1976, BIOMED ENG, V11, P81