DETERMINATION OF ANTIMONY IN WASTE-WATER WITH CHROMAZUROL-S BY BETA-CORRECTION SPECTROPHOTOMETRY

被引:50
作者
GAO, HW [1 ]
ZHANG, PF [1 ]
机构
[1] HUAIBEI COAL TEACHERS COLL,DEPT CHEM,HUAIBEI 235000,PEOPLES R CHINA
关键词
BETA CORRECTION SPECTROPHOTOMETRY; ANTIMONY DETERMINATION; CHROMAZUROL S;
D O I
10.1039/an9941902109
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Beta correction absorbance can eliminate completely the interference from the excess of chromogenic reagent to give the real absorbance of the complex produced. The reaction of antimony and Chromazurol S was developed in pH 5-6 buffer solution. The determination of trace amounts of antimony in waste water was studied by beta correction spectrophotometry using this reaction. The results showed that Beer's law was obeyed over the concentration range O-1.0 mg l(-1) of antimony. The detection limit is 0.009 mg l(-1), which is low enough to determine antimony in environmental waters.
引用
收藏
页码:2109 / 2111
页数:3