AN INVESTIGATION INTO THE EFFECT OF PROTECTIVE DEVICES ON THE DOSE TO RADIOSENSITIVE ORGANS IN THE HEAD AND NECK

被引:47
作者
MARSHALL, NW [1 ]
FAULKNER, K [1 ]
CLARKE, P [1 ]
机构
[1] ROYAL VICTORIA INFIRM,DEPT RADIOL,NEWCASTLE TYNE NE1 4LP,TYNE & WEAR,ENGLAND
关键词
DIAGNOSTIC RADIOLOGY; PROTECTIVE DEVICES; RADIATION PROTECTION;
D O I
10.1259/0007-1285-65-777-799
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A series of experiments were performed to determine the dose reduction afforded to radiosensitive organs in the head and neck by various protective devices. These included spectacles with plastic, standard glass, photochromic and lead-glass lenses, a thyroid collar and a lead-acrylic face mask. The measurements were performed using an anthropomorphic phantom loaded with lithium fluoride thermoluminescent dosemeters, in conditions realistic of clinical practice. Irradiations were performed using scattered radiation produced by a pelvic phantom, for X-ray beams generated at 80 kVp and 110 KVp. It was found that the reduction in dose to the lens of the eye ranged between 0% and 97%, whilst the dose to the thyroid and oesophagus was reduced by between 76% and 97%, and was dependent on the protective device and tube potential employed. A reduction in brain dose of up to 81% was also measured, for the lead-acrylic face mask. Also presented is the ratio of organ dose to dose to the bridge of the nose for thyroid, oesophagus, brain and sinuses, as measured for the case of no head or neck protection.
引用
收藏
页码:799 / 802
页数:4
相关论文
共 11 条
[1]   VALUE OF CONVENTIONAL EYEGLASSES FOR X-RAY PROTECTION [J].
ARDRAN, GM ;
CROOKS, HE .
RADIOLOGY, 1978, 129 (03) :815-816
[2]   EYE LENS PROTECTION FOR RADIOLOGICAL PERSONNEL [J].
BERGSTROM, K ;
JORULF, H ;
LOFROTH, PO .
RADIOLOGY, 1977, 124 (03) :839-840
[3]   EYE LENS DOSES IN CAROTID ANGIOGRAPHY [J].
BERGSTROM, K ;
GUSTAFSSON, M ;
DAHLIN, H ;
NYLEN, O .
ACTA RADIOLOGICA-DIAGNOSIS, 1972, 12 (02) :134-+
[4]   PROTECTIVE EFFECT OF SPECTACLES [J].
DAY, MJ ;
FORSTER, E .
BRITISH JOURNAL OF RADIOLOGY, 1981, 54 (638) :137-138
[5]   AN ASSESSMENT OF THE RADIATION-DOSE RECEIVED BY STAFF USING FLUOROSCOPIC EQUIPMENT [J].
FAULKNER, K ;
MOORES, BM .
BRITISH JOURNAL OF RADIOLOGY, 1982, 55 (652) :272-276
[6]   ESTIMATION OF EFFECTIVE DOSE EQUIVALENT TO STAFF IN DIAGNOSTIC-RADIOLOGY [J].
FAULKNER, K ;
HARRISON, RM .
PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (01) :83-91
[7]   AN INVESTIGATION OF THE RADIATION-DOSE TO STAFF DURING CARDIAC RADIOLOGICAL STUDIES [J].
JEANS, SP ;
FAULKNER, K ;
LOVE, HG ;
BARDSLEY, RA .
BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (689) :419-428
[8]   DOSES TO HEAD AND ARMS OF RADIOLOGISTS DURING FLUOROSCOPY [J].
LAW, J .
BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (686) :187-188
[9]   EYE DOSE LIMITS AND THE USE OF OVERCOUCH AND UNDERCOUCH X-RAY IMAGE INTENSIFIER SYSTEMS [J].
PALMER, KE ;
WRIGHT, IH .
BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (696) :1221-1223
[10]   EFFECTIVENESS OF LEAD LENSES IN REDUCING RADIATION EXPOSURE [J].
RICHMAN, AH ;
CHAN, B ;
KATZ, M .
RADIOLOGY, 1976, 121 (02) :357-359