EVALUATION OF EIMAC LAMP AS EXCITATION SOURCE FOR MOLECULAR FLUORESCENCE WITH APPLICATION TO QUANTITATION OF ERGOTAMININE IN PLASMA BY HIGH-PRESSURE LIQUID-CHROMATOGRAPHY

被引:22
作者
PERCHALSKI, RJ
WINEFORDNER, JD
WILDER, BJ
机构
[1] UNIV FLORIDA,DEPT CHEM,GAINESVILLE,FL
[2] UNIV FLORIDA,DEPT NEUROL,GAINESVILLE,FL
[3] VET ADM HOSP,RES SERV,GAINESVILLE,FL 32602
[4] VET ADM HOSP,NEUROL SECT,GAINESVILLE,FL
关键词
D O I
10.1021/ac60362a056
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
引用
收藏
页码:1993 / 1999
页数:7
相关论文
共 43 条
[1]  
AGHAJANIAN GK, 1964, CLIN PHARMACOL THER, V5, P611
[2]   GAS CHROMATOGRAPHY OF ERGOT ALKALOIDS [J].
AGURELL, S ;
OHLSSON, A .
JOURNAL OF CHROMATOGRAPHY, 1971, 61 (02) :339-&
[3]  
ALEXANDER TG, 1960, J ASSOC OFF AGR CHEM, V43, P224
[4]   THE DISTRIBUTION AND METABOLISM OF LYSERGIC ACID DIETHYLAMIDE [J].
AXELROD, J ;
BRADY, RO ;
WITKOP, B ;
EVARTS, EV .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1957, 66 (03) :435-444
[5]   COMPARISON OF PHOTOMETRIC DETECTORS FOR HIGH-SPEED LIQUID-CHROMATOGRAPHY [J].
BAKER, DR ;
WILLIAMS, RC ;
STEICHEN, JC .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1974, 12 (09) :499-505
[6]  
BOWD A, 1973, J CHEM SOC P2, V10, P1312
[7]   EVALUATION OF 150-W EIMAC XENON LAMP FOR ATOMIC FLUORESCENCE FLAME SPECTROMETRY [J].
BRATZEL, MP ;
DAGNALL, RM ;
WINEFORD.JD .
ANALYTICA CHIMICA ACTA, 1970, 52 (01) :157-&
[8]  
BRAZEAU P, 1970, PHARMACOLOGICAL BASI, P898
[9]   ANALYSIS OF PHENOLS BY DERIVATIZATION AND HIGH-SPEED LIQUID-CHROMATOGRAPHY [J].
CASSIDY, RM ;
LEGAY, DS ;
FREI, RW .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1974, 12 (02) :85-89
[10]   FLUORESCENCE DETECTOR FOR HIGH-SPEED LIQUID CHROMATOGRAPHY [J].
CASSIDY, RM ;
FREI, RW .
JOURNAL OF CHROMATOGRAPHY, 1972, 72 (02) :293-&