SEQUENTIAL SPECIATION OF SELENIUM BY FLOW-INJECTION CATHODIC STRIPPING VOLTAMMETRY

被引:23
作者
BRYCE, DW [1 ]
IZQUIERDO, A [1 ]
DECASTRO, MDL [1 ]
机构
[1] UNIV CORDOBA,FAC SCI,DEPT ANALYT CHEM,E-14004 CORDOBA,SPAIN
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1995年 / 351卷 / 4-5期
关键词
D O I
10.1007/BF00322914
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A semi-automatic continuous method for the determination of Se(IV) based on flow-injection cathodic stripping voltammetry (FICSV) is reported. The flow injection approach incorporates a thin mercury film on glassy carbon as the working electrode, on which Se(IV) is deposited at an applied potential of 0.0 V. A cathodic scan (from 0.0 to - 0.9 V) is applied and the Se is stripped at - 0.54 V, providing a current intensity proportional to the Se(IV) concentration in the sample. This method features a linear determination range between 0.5 and 30 ng/ml (r(2) = 0.998, RSD = 3.6%). The non-interference levels (foreign species to analyte ratio) are 2.5 : 1 for Cu(II), 7.5:1 for Pb(II), 35:1 for Cd(II), 250:1 for Zn(II) and 500:1 for Fe(III). After developing the method for Se(IV), the speciation of this element has been performed by sequential injection of the dissolved sample into a carrier which may or may not have been previously reduced off-line thus determining the sum (Se(IV) + Se(VI)) or only Se(IV), respectively. The method has been applied to selenium speciation in water samples.
引用
收藏
页码:433 / 437
页数:5
相关论文
共 43 条
[1]   DETERMINATION OF SELENIUM, COPPER, LEAD AND CADMIUM IN BIOLOGICAL-MATERIALS BY DIFFERENTIAL PULSE STRIPPING VOLTAMMETRY [J].
ADELOJU, SB ;
BOND, AM ;
HUGHES, HC .
ANALYTICA CHIMICA ACTA, 1983, 148 (APR) :59-69
[2]   CRITICAL-EVALUATION OF SOME WET DIGESTION METHODS FOR THE STRIPPING VOLTAMMETRIC DETERMINATION OF SELENIUM IN BIOLOGICAL-MATERIALS [J].
ADELOJU, SB ;
BOND, AM ;
BRIGGS, MH .
ANALYTICAL CHEMISTRY, 1984, 56 (13) :2397-2401
[3]   MULTIELEMENT DETERMINATION IN BIOLOGICAL-MATERIALS BY DIFFERENTIAL PULSE VOLTAMMETRY [J].
ADELOJU, SB ;
BOND, AM ;
BRIGGS, MH .
ANALYTICAL CHEMISTRY, 1985, 57 (07) :1386-1390
[4]   STRIPPING VOLTAMMETRIC DETERMINATION OF SELENIUM IN BIOLOGICAL-MATERIALS BY DIRECT CALIBRATION [J].
ADELOJU, SB ;
BOND, AM ;
BRIGGS, MH ;
HUGHES, HC .
ANALYTICAL CHEMISTRY, 1983, 55 (13) :2076-2082
[5]  
AHMAD R, 1983, ANALYST, V108, P835
[6]   DETERMINATION OF SELENIUM(IV) BY ANODIC-STRIPPING VOLTAMMETRY IN FLOW SYSTEM WITH ION-EXCHANGE SEPARATION [J].
ANDREWS, RW ;
JOHNSON, DC .
ANALYTICAL CHEMISTRY, 1976, 48 (07) :1056-1060
[7]   DETERMINATION OF SELENIUM(IV) BY ANODIC-STRIPPING VOLTAMMETRY USING EXTRACTION WITH PENTYL ALCOHOL [J].
AYDIN, H ;
YAHAYA, AH .
ANALYST, 1992, 117 (01) :43-45
[8]   PARAMETER EVALUATION FOR THE DETERMINATION OF SELENIUM BY CATHODIC STRIPPING VOLTAMMETRY AT THE HANGING MERCURY DROP ELECTRODE [J].
BALTENSPERGER, U ;
HERTZ, J .
ANALYTICA CHIMICA ACTA, 1985, 172 (JUN) :49-56
[9]   DETERMINATION OF VERY LOW-LEVELS OF SELENIUM(IV) IN SEA-WATER BY DIFFERENTIAL-PULSE CATHODIC STRIPPING VOLTAMMETRY AFTER EXTRACTION OF THE 3,3'-DIAMINOBENZIDINE PIAZSELENOL [J].
BREYER, P ;
GILBERT, BP .
ANALYTICA CHIMICA ACTA, 1987, 201 :33-41
[10]  
BURK RF, 1976, TRACE ELEMENT HUMAN, V2