COMPUTER-ANALYSIS AND PATTERN-RECOGNITION OF DOPPLER BLOOD-FLOW SPECTRA FOR DISEASE CLASSIFICATION IN THE LOWER-LIMB ARTERIES

被引:13
作者
ALLARD, L
LANGLOIS, YE
DURAND, LG
ROEDERER, GO
BEAUDOIN, M
CLOUTIER, G
ROY, P
ROBILLARD, P
机构
[1] MONTREAL GEN HOSP, HOTEL DIEU, NONINVAS CARDIOVASC RES LAB, MONTREAL H2W 1T8, QUEBEC, CANADA
[2] MONTREAL GEN HOSP, HOTEL DIEU, DIV RADIOL, MONTREAL H2W 1T8, QUEBEC, CANADA
关键词
ULTRASOUND; DOPPLER TECHNIQUES; ATHEROSCLEROSIS; PERIPHERAL ARTERY DISEASE; SPECTRAL ANALYSIS; FREQUENCY CONTOUR ESTIMATION; PATTERN RECOGNITION;
D O I
10.1016/0301-5629(91)90042-U
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In the present study, a computer processing method was developed to objectively classify disease in the lower limb arteries evaluated by noninvasive ultrasonic duplex scanning. This method analyzes Doppler blood flow signals, extracts diagnostic features from Doppler spectrograms and classifies the severity of the disease into three categories of diameter reduction (0-19%, 20-49% and 50-99%). The features investigated were based on frequency features obtained at peak systole, spectral broadening indices and normalized amplitudes of the power spectrogram computed in various positive and negative frequency bands. A total of 379 arterial segments studied from the aorta to the popliteal artery were classified using a pattern recognition method based on the Bayes model. Two classification schemes using a two-node decision rule were tested. Both schemes gave similar results, the first one provided an overall accuracy of 83% (Kappa = 0.42) and the second an overall accuracy of 81% (Kappa = 0.35) when compared with conventional biplane contrast arteriography. These performances, especially for the 0 to 19% lesion category, are better than the one obtained by the technologist (accuracy = 76% and Kappa = 0.33), based on visual interpretation of the Doppler spectrograms. To recognize hemodynamically significant stenoses (50-99% lesions), the pattern recognition system has a sensitivity and a specificity of 50% and 99%, respectively, using classification scheme I. With classification scheme II, the sensitivity and the specificity are 50% and 98%, respectively. Visual interpretation of the Doppler spectrograms leads to a sensitivity and a specificity of 50% and 98%, respectively. These results are the first to be obtained by a pattern recognition system in classifying lower limb arterial stenoses.
引用
收藏
页码:211 / 223
页数:13
相关论文
共 38 条
[1]  
BAKER JD, 1988, ULTRASOUND MED BIOL, V15, P13
[2]   ANALYSIS OF FEMORAL-ARTERY DOPPLER SIGNALS BY LAPLACE TRANSFORM DAMPING METHOD [J].
BAKER, JD ;
MACHLEDER, HI ;
SKIDMORE, R .
JOURNAL OF VASCULAR SURGERY, 1984, 1 (04) :520-524
[3]  
BEACH KW, 1989, J VASC TECH, V13, P65
[4]   DIGITAL FOURIER TECHNIQUES IN THE DIAGNOSIS AND QUANTIFICATION OF AORTIC-STENOSIS WITH PULSED-DOPPLER ECHOCARDIOGRAPHY [J].
CANNON, SR ;
RICHARDS, KL ;
ROLLWITZ, WT .
JOURNAL OF CLINICAL ULTRASOUND, 1982, 10 (03) :101-107
[5]   CHARACTERIZATION OF SPECTRAL BROADENING OF DOPPLER SIGNALS RECORDED IN THE LEFT-VENTRICULAR OUTFLOW TRACT OF PATIENTS WITH A VALVULAR AORTIC-STENOSIS [J].
CLOUTIER, G ;
LEMIRE, F ;
DURAND, LG ;
LATOUR, Y ;
JARRY, M ;
SOLIGNAC, A ;
ALLARD, L ;
LANGLOIS, YE .
IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 :67-68
[6]   COMPUTER EVALUATION OF DOPPLER SPECTRAL ENVELOPE AREA IN PATIENTS HAVING A VALVULAR AORTIC-STENOSIS [J].
CLOUTIER, G ;
LEMIRE, F ;
DURAND, LG ;
LATOUR, Y ;
LANGLOIS, YE .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (03) :247-260
[7]   A COEFFICIENT OF AGREEMENT FOR NOMINAL SCALES [J].
COHEN, J .
EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 1960, 20 (01) :37-46
[8]   COMPARISON OF PATTERN-RECOGNITION METHODS FOR COMPUTER-ASSISTED CLASSIFICATION OF SPECTRA OF HEART SOUNDS IN PATIENTS WITH A PORCINE BIOPROSTHETIC VALVE IMPLANTED IN THE MITRAL POSITION [J].
DURAND, LG ;
BLANCHARD, M ;
CLOUTIER, G ;
SABBAH, HN ;
STEIN, PD .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (12) :1121-1129
[9]   THE RELATIONSHIP BETWEEN ULTRASONIC PULSATILITY INDEX AND PROXIMAL ARTERIAL-STENOSIS IN A CANINE MODEL [J].
EVANS, DH ;
BARRIE, WW ;
ASHER, MJ ;
BENTLEY, S ;
BELL, PRF .
CIRCULATION RESEARCH, 1980, 46 (04) :470-475
[10]  
FEINSTEIN AR, 1977, CLIN BIOSTATISTICS, P214