MECHANISMS OF ANGIOPLASTY IN HEMODIALYSIS FISTULA STENOSES EVALUATED BY INTRAVASCULAR ULTRASOUND

被引:94
作者
DAVIDSON, CJ [1 ]
NEWMAN, GE [1 ]
SHEIKH, KH [1 ]
KISSLO, K [1 ]
STACK, RS [1 ]
SCHWAB, SJ [1 ]
机构
[1] DUKE UNIV,MED CTR,DIV MED,DURHAM,NC 27710
关键词
D O I
10.1038/ki.1991.185
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Quantification of luminal dimensions and the mechanisms by which angioplasty (PTA) corrects non-atheroma venous fistula stenoses have been poorly studied. In 38 consecutive percutaneous balloon angioplasties of hemodialysis fistula stenoses, catheterbased, mechanically-rotated intravascular ultrasound (IVUS) images were obtained along with cineangiography. Images from 24 brachial vein, 11 central vein, 2 graft anastomoses, and 1 brachial artery were quantitatively and qualitatively evaluated. Semiautomated quantitative angiographic stenosis was 64 +/- 13% pre-PTA and reduced to 36 +/- 19% post-PTA (P < 0.001). Post-PTA IVUS minimal lesion diameter and cross sectional area were 5.7 +/- 1.5 mm and 2.9 +/- 1.5 mm2, respectively. With IVUS, mechanisms observed were: vessel dissection in 16 (42%), arterial stretch (defined as vessel diameter: balloon diameter ratio = 0.75 to 1.0) in 19 (50%), and elastic recoil (defined as vessel diameter: balloon diameter ratio < 0.75) in 19 (50%). Compared to angiography, morphologic information provided by IVUS were plaque composition (hard 11%, soft 89%), plaque topography (eccentric 94%, concentric 6%), thrombus (IVUS: N = 6 vs. angio: N = 1), dissection (IVUS: N = 16 vs. angio: N = 1). Thus, IVUS can evaluate lesion morphology and define luminal dimensions after angioplasty. Mechanisms of successful angioplasty of hemodialysis fistula stenosis occur primarily by vessel stretching and dissection, and significant post-PTA narrowing is due to elastic recoil.
引用
收藏
页码:91 / 95
页数:5
相关论文
共 17 条
  • [1] MECHANISM OF TRANS-LUMINAL ANGIOPLASTY
    BLOCK, PC
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (12) : C69 - C71
  • [2] INTRAVASCULAR ULTRASONOGRAPHY VERSUS DIGITAL SUBTRACTION ANGIOGRAPHY - A HUMAN INVIVO COMPARISON OF VESSEL SIZE AND MORPHOLOGY
    DAVIDSON, CJ
    SHEIKH, KH
    HARRISON, JK
    HIMMELSTEIN, SI
    LEITHE, ME
    KISSLO, KB
    BASHORE, TM
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (03) : 633 - 636
  • [3] ARTERIAL-WALL CHARACTERISTICS DETERMINED BY INTRAVASCULAR ULTRASOUND IMAGING - AN INVITRO STUDY
    GUSSENHOVEN, EJ
    ESSED, CE
    LANCEE, CT
    MASTIK, F
    FRIETMAN, P
    VANEGMOND, FC
    REIBER, J
    BOSCH, H
    VANURK, H
    ROELANDT, J
    BOM, N
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (04) : 947 - 952
  • [4] BALLOON ANGIOPLASTY OF COARCTATION OF THE AORTA EVALUATED WITH INTRAVASCULAR ULTRASOUND IMAGING
    HARRISON, JK
    SHEIKH, KH
    DAVIDSON, CJ
    KISSLO, KB
    LEITHE, ME
    HIMMELSTEIN, SI
    KANTER, RJ
    BASHORE, TM
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) : 906 - 909
  • [5] COMPARISON OF COMPLICATIONS DURING PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY FROM 1977 TO 1981 AND FROM 1985 TO 1986 - THE NATIONAL-HEART-LUNG-AND-BLOOD-INSTITUTE PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY REGISTRY
    HOLMES, DR
    HOLUBKOV, R
    VLIETSTRA, RE
    KELSEY, SF
    REEDER, GS
    DORROS, G
    WILLIAMS, DO
    COWLEY, MJ
    FAXON, DP
    KENT, KM
    BENTIVOGLIO, LG
    DETRE, K
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 12 (05) : 1149 - 1155
  • [6] AUTOMATED QUANTITATIVE CORONARY ARTERIOGRAPHY - MORPHOLOGICAL AND PHYSIOLOGICAL VALIDATION IN VIVO OF A RAPID DIGITAL ANGIOGRAPHIC METHOD
    MANCINI, GBJ
    SIMON, SB
    MCGILLEM, MJ
    LEFREE, MT
    FRIEDMAN, HZ
    VOGEL, RA
    [J]. CIRCULATION, 1987, 75 (02) : 452 - 460
  • [7] POLYTETRAFLUOROETHYLENE GRAFT-SURVIVAL IN HEMODIALYSIS
    MUNDA, R
    FIRST, MR
    ALEXANDER, JW
    LINNEMANN, CC
    FIDLER, JP
    KITTUR, D
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1983, 249 (02): : 219 - 222
  • [8] VASCULAR ACCESS FOR HEMODIALYSIS - PATENCY RATES AND RESULTS OF REVISION
    PALDER, SB
    KIRKMAN, RL
    WHITTEMORE, AD
    HAKIM, RM
    LAZARUS, JM
    TILNEY, NL
    [J]. ANNALS OF SURGERY, 1985, 202 (02) : 235 - 239
  • [9] INTRACARDIAC, INTRAVASCULAR, 2-DIMENSIONAL, HIGH-FREQUENCY ULTRASOUND IMAGING OF PULMONARY-ARTERY AND ITS BRANCHES IN HUMANS AND ANIMALS
    PANDIAN, NG
    WEINTRAUB, A
    KREIS, A
    SCHWARTZ, SL
    KONSTAM, MA
    SALEM, DN
    [J]. CIRCULATION, 1990, 81 (06) : 2007 - 2012
  • [10] DETECTION OF INTRAARTERIAL THROMBUS BY INTRAVASCULAR HIGH-FREQUENCY 2-DIMENSIONAL ULTRASOUND IMAGING INVITRO AND INVIVO STUDIES
    PANDIAN, NG
    KREIS, A
    BROCKWAY, B
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1990, 65 (18) : 1280 - 1283