PREDICTION OF GLOMERULAR-FILTRATION RATE USING AMINOGLYCOSIDE CLEARANCE IN CRITICALLY ILL MEDICAL PATIENTS

被引:37
作者
ZAROWITZ, BJ
ROBERT, S
PETERSON, EL
机构
[1] WAYNE STATE UNIV, DEPT PHARM PRACTICE, DETROIT, MI 48202 USA
[2] HENRY FORD HOSP, DIV BIOSTAT & RES EPIDEMIOL, DETROIT, MI 48202 USA
关键词
D O I
10.1177/106002809202601001
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
OBJECTIVE: The aim of this preliminary investigation was to evaluate the use of aminoglycoside serum concentrations as a surrogate measure of the glomerular filtration rate (GFR) in comparison with other measured and empiric methods against inulin, the criterion standard measure of GFR. DESIGN: A consecutive sample of all eligible patients. SETTING: An eight-bed medical intensive care unit in a university-affiliated tertiary-care teaching hospital. PATIENTS: Ten critically ill medical patients receiving gentamicin or tobramycin for presumed or documented gram-negative bacillary infection were enrolled in the study. The patients were mechanically ventilated and had underlying organ system dysfunction. All ten patients completed the study. INTERVENTION: Patients underwent renal functional assessment by measured inulin (Cl(in)) and 24-hour urinary creatinine clearance (Cl(cr)). Aminoglycoside serum concentrations were used to estimate GFR and were compared with the two measured methods and a creatinine clearance calculated with the Cockcroft-Gault method (Cl(CG)). All evaluations were performed the same day. RESULTS: Cl(in) averaged 51.6 +/- 35.0 mL/min and serum creatinine ranged from 0.3 to 5.4 mg/dL (26.5 to 477.3 mumol/L). Steady-state peak and trough aminoglycoside concentrations were 6.1 +/- 1.4 and 1.3 +/- 0.9 mug/mL, respectively. There were no statistically significant differences between the various methods, although the aminoglycoside-calculated GFR (Cl(amg)) 95 percent confidence intervals were smaller than Cl(cr) and Cl(CG) compared with Cl(in). Mean absolute errors were smaller with Cl(amg) than with Cl(cr) and Cl(CG). Regression results indicated that only Cl(amg) and Cl(CG) demonstrated agreement with Cl(in) (lines not different from y=x). However, the Cl(amg) showed closer agreement, with a mean square error almost half that of Cl(CG) (9.6 vs. 18. 1). CONCLUSIONS: Cl(amg) can be used routinely as an estimate of GFR in critically ill patients, with less error than empiric methods.
引用
收藏
页码:1205 / 1210
页数:6
相关论文
共 42 条
[1]   CLINICAL APPRAISAL OF CREATININE CLEARANCE AS A MEASUREMENT OF GLOMERULAR-FILTRATION RATE [J].
BAUER, JH ;
BROOKS, CS ;
BURCH, RN .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1982, 2 (03) :337-346
[2]   RENAL FUNCTIONAL RESERVE IN HUMANS - EFFECT OF PROTEIN-INTAKE ON GLOMERULAR-FILTRATION RATE [J].
BOSCH, JP ;
SACCAGGI, A ;
LAUER, A ;
RONCO, C ;
BELLEDONNE, M ;
GLABMAN, S .
AMERICAN JOURNAL OF MEDICINE, 1983, 75 (06) :943-950
[3]  
BREZIS M, 1991, KIDNEY, P993
[4]   THE ASSESSMENT OF RISK-FACTORS IN 462 PATIENTS WITH ACUTE RENAL-FAILURE [J].
BULLOCK, ML ;
UMEN, AJ ;
FINKELSTEIN, M ;
KEANE, WF .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1985, 5 (02) :97-103
[5]   APPARENT REDUCTION OF ENDOGENOUS CREATININE CLEARANCE BY SALICYLATE TREATMENT [J].
BURRY, HC ;
DIEPPE, PA .
BRITISH MEDICAL JOURNAL, 1976, 1 (6026) :16-17
[6]   CREATININE - AN INADEQUATE FILTRATION MARKER IN GLOMERULAR-DISEASES [J].
CARRIE, BJ ;
GOLBETZ, HV ;
MICHAELS, AS ;
MYERS, BD .
AMERICAN JOURNAL OF MEDICINE, 1980, 69 (02) :177-182
[7]   PREDICTION OF CREATININE CLEARANCE FROM SERUM CREATININE [J].
COCKCROFT, DW ;
GAULT, MH .
NEPHRON, 1976, 16 (01) :31-41
[8]   ACUTE RENAL-FAILURE IN THE INTENSIVE-CARE UNIT .1. [J].
CORWIN, HL ;
BONVENTRE, JV .
INTENSIVE CARE MEDICINE, 1988, 14 (01) :10-16
[9]   COMPARISON OF AMINOGLYCOSIDE CLEARANCE AND CALCULATED SERUM CREATININE CLEARANCES [J].
DEETER, RG ;
KRAUSS, EA ;
PENN, F ;
NAHACZEWSKI, AE .
THERAPEUTIC DRUG MONITORING, 1989, 11 (02) :155-161
[10]   GENTAMICIN THERAPY [J].
DEVINE, BJ .