Determination of salbutamol sulfate in medicaments by capillary electrophoresis with contactless conductivity detection

被引:4
作者
Chen Changguo [1 ]
Li Hong [1 ]
Fan Yujing [1 ]
机构
[1] Chongqing Univ, Coll Chem & Chem Engn, Chongqing 400044, Peoples R China
关键词
capillary electrophoresis (CE); contactless conductivity detection; salbutamol sulfate; salbutamol sulfate tablet; salbutamol sulfate aerosol;
D O I
10.3724/SP.J.1123.2011.00137
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for the determination of salbutamol sulfate in medicaments by capillary electrophoresis with contactless conductivity detection has been developed. The effects of several important factors, such as nonaqueous and aqueous solvents, background electrolyte and its concentration as well as the pH, separation voltage, sample injection time, excitation voltage and excitation frequency > were investigated. The optimized separation conditions were as follows: the running buffer was an aqueous solution (pH 2. 7) containing 15 mmoVL lactic acid the separation voltage was 10 kV, the electrokinetic injection time was 3 s at 10 kV, the excitation voltage was 60 V, and the excitation frequency was 120 kHz. The results have shown that there was a linear relationship (r = 0. 995) between the response of the peak area and the mass concentration of salbutamol sulfate in the range from 9. 60 to 48. 0 mg/L > and the limits of detection (S/N = 3) was 1. 92 mg/L. The relative standard deviation for the migration time of salbutamol sulfate was 2. 7%. The method has been successfully applied in the determination of the contents in the tablet and aerosol of salbutamol sulfate separately. The results were in accordance with the values marked by the pharmaceutical industry. Moreover, the recoveries were 90% -113%. This simple and quick analytical method can be used for determining salbutamol sulfate.
引用
收藏
页码:137 / 140
页数:4
相关论文
共 17 条
[1]   AC impedance characteristics of capacitively coupled contactless conductivity detector cell in capillary electrophoresis [J].
Chen, Chang Guo ;
Li, Lei Guang ;
Si, Yu Jun ;
Li, Yu Ping .
ELECTROCHIMICA ACTA, 2009, 54 (27) :6959-6962
[2]  
[方卢秋 Fang Luqiu], 2003, [分析测试学报, Journal of Instrumental Analysis], V22, P25
[3]   A novel sulfate polymeric membrane sensor based on a new bis-pyrylium derivative [J].
Ganjali, MR ;
Shirvani-Arani, S ;
Nourozi, P ;
Salimzadeh, D ;
Faal-Rastegar, M ;
Moghimi, A .
ELECTROANALYSIS, 2004, 16 (12) :1009-1013
[4]  
Huang X P, 2005, MODERN PREVENTIVE ME, V32, P562
[5]  
Lau JHW, 2004, J AOAC INT, V87, P31
[6]  
[李全文 LI QuanWen], 2006, [应用化学, Chinese Journal of Applied Chemistry], V23, P1317
[7]  
[林冬青 Lin Dongqing], 2005, [药物分析杂志, Chinese Journal of Pharmaceutical Analysis], V25, P709
[8]  
Liu W, 2006, CHINA PHARM, V15, P26
[9]  
Min C L, 2009, CHINESE PHARM AFFAIR, V23, P370
[10]  
Pharmacopoeia Commission of People' s Republic of China, 2000, PHARM PEOPL REP CH 2, P871