SUSTAINED INFLATIONS IMPROVE RESPIRATORY COMPLIANCE DURING HIGH-FREQUENCY OSCILLATORY VENTILATION BUT NOT DURING LARGE TIDAL VOLUME POSITIVE-PRESSURE VENTILATION IN RABBITS

被引:55
作者
BOND, DM
MCALOON, J
FROESE, AB
机构
[1] QUEENS UNIV,DEPT ANAESTHESIA,KINGSTON,ON,CANADA
[2] QUEENS UNIV,DEPT PAEDIAT,KINGSTON,ON,CANADA
关键词
HIGH-FREQUENCY OSCILLATION; MECHANICAL VENTILATION; POSITIVE-PRESSURE VENTILATION; TIDAL VOLUME; POSITIVE END-EXPIRATORY PRESSURE; LUNG VOLUME MEASUREMENTS; PULMONARY SURFACTANT; PULMONARY EMERGENCIES;
D O I
10.1097/00003246-199408000-00011
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To determine whether volume recruitment maneuvers that induce significant lung reexpansion during high-frequency oscillatory ventilation are also of value during conventional positive-pressure ventilation. Design: Crossover comparison of volume recruitment maneuvers administered during high-frequency oscillatory ventilation and positive-pressure ventilation in normal and surfactant-deficient adult rabbits. Setting: Laboratory. Subjects: Nineteen adult New Zealand white rabbits (weight 2.3 to 3.3 kg). Methods: Respiratory system compliance was measured plethysmographically before and after sustained inflations in six normal and five saline-lavaged anesthetized rabbits, using both ventilators over a range of mean and end-expiratory pressures. Results: Under conditions where sustained inflations during high-frequency oscillatory ventilation at 15 Hz increased respiratory system compliance 50 +/- 28%, sustained inflations during conventional positive-pressure ventilation at a rate of 30 to 40 breaths/min and tidal volumes of 14 to 17 mL/kg did not change respiratory system compliance (mean change 3 +/- 9%). Sustained inflations during conventional positive-pressure ventilation could not be made effective by increasing the positive end-expiratory pressure level to equal the mean pressure during high-frequency oscillatory ventilation. Sustained inflations on conventional positive-pressure ventilation remained ineffective up to positive end-expiratory pressure levels of 17.5 cm H2O. In lavaged rabbits, sustained inflations increased respiratory system compliance 49 +/- 14% during high-frequency oscillatory ventilation and 0 +/- 3% during conventional positive-pressure ventilation. Sustained inflations increased compliance significantly during conventional positive-pressure ventilation only when ventilating with tidal volumes of 7 mL/kg and low end-expiratory pressure. Conclusions: Active recruitment of lung volume during high-frequency oscillatory ventilation appears necessary, because small pressure/volume cycles adequate to support high-frequency gas transport are not able to reexpand atelectatic lung units without the aid of a sustained inflation. We conclude that volume recruitment maneuvers improve respiratory system compliance substantially during high-frequency oscillatory ventilation at 15 Hz, but these maneuvers offer potential risk and no benefit during conventional positive-pressure ventilation with large tidal volumes or when using smaller tidal volumes and high levels of positive end-expiratory pressure.
引用
收藏
页码:1269 / 1277
页数:9
相关论文
共 26 条
[1]   IMPAIRED OXYGENATION IN SURGICAL PATIENTS DURING GENERAL ANESTHESIA WITH CONTROLLED VENTILATION - A CONCEPT OF ATELECTASIS [J].
BENDIXEN, HH ;
HEDLEYWHYTE, J ;
LAVER, MB .
NEW ENGLAND JOURNAL OF MEDICINE, 1963, 269 (19) :991-+
[2]  
BENDIXEN HH, 1965, RESPIRATORY CARE, P145
[3]  
BERGMAN NA, 1972, ANESTHESIOLOGY, V37, P623
[4]   THE ELASTIC PRESSURE-VOLUME CURVES OF THE LUNGS AND THORAX OF THE LIVING RABBIT [J].
BERNSTEIN, L .
JOURNAL OF PHYSIOLOGY-LONDON, 1957, 138 (03) :473-487
[5]   VOLUME RECRUITMENT MANEUVERS ARE LESS DELETERIOUS THAN PERSISTENT LOW LUNG-VOLUMES IN THE ATELECTASIS-PRONE RABBIT LUNG DURING HIGH-FREQUENCY OSCILLATION [J].
BOND, DM ;
FROESE, AB .
CRITICAL CARE MEDICINE, 1993, 21 (03) :402-412
[6]  
BRYAN AC, 1986, AM REV RESPIR DIS, V133, P928
[7]   LUNG-VOLUME RECRUITMENT DURING HIGH-FREQUENCY OSCILLATION IN ATELECTASIS-PRONE RABBITS [J].
BYFORD, LJ ;
FINKLER, JH ;
FROESE, AB .
JOURNAL OF APPLIED PHYSIOLOGY, 1988, 64 (04) :1607-1614
[8]   VENTILATORY MANAGEMENT OF INFANT BABOONS WITH HYALINE-MEMBRANE DISEASE - THE USE OF HIGH-FREQUENCY VENTILATION [J].
DELEMOS, RA ;
COALSON, JJ ;
GERSTMANN, DR ;
NULL, DM ;
ACKERMAN, NB ;
ESCOBEDO, MB ;
ROBOTHAM, JL ;
KUEHL, TJ .
PEDIATRIC RESEARCH, 1987, 21 (06) :594-602
[9]   INTERMITTENT DEEP BREATHS AND COMPLIANCE DURING ANESTHESIA IN MAN [J].
EGBERT, LD ;
BENDIXEN, HH ;
LAVER, MB .
ANESTHESIOLOGY, 1963, 24 (01) :57-+
[10]  
Fairley H B, 1976, Respir Care, V21, P1127