QUANTITATIVE MEASUREMENT OF VELOCITY AT MULTIPLE POSITIONS USING COMB EXCITATION AND FOURIER VELOCITY ENCODING

被引:28
作者
DUMOULIN, CL [1 ]
DOORLY, DJ [1 ]
CARO, CG [1 ]
机构
[1] UNIV LONDON IMPERIAL COLL SCI TECHNOL & MED,LONDON SW7 2AZ,ENGLAND
关键词
D O I
10.1002/mrm.1910290110
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An MR imaging technique that simultaneously acquires Fourier velocity encoded data from multiple stations is described. The technique employs a comb excitation rf pulse that excites an arbitrary number of slices. As the Fourier velocity phase encoding gradient pulse is advanced, the phase of each slice is the comb is advanced by a unique amount. This causes the signals from the spins in a particular slice to appear at a position in the phase encoding direction, which is the sum of the spin velocity and an offset arising from the phase increment given to that excitation slice. Acquisition of spin velocity information occurs simultaneously for all slices, permitting the calculation of wave velocities arising from pulsatile flow. These wave velocities can then be used to determine vessel distensibility.
引用
收藏
页码:44 / 52
页数:9
相关论文
共 28 条
[1]   CALCULATION OF PRESSURE-GRADIENTS FROM MR VELOCITY DATA IN A LAMINAR-FLOW MODEL [J].
ADLER, RS ;
CHENEVERT, TL ;
FOWLKES, JB ;
PIPE, J ;
RUBIN, JM .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (03) :483-488
[2]   MR FLOW IMAGING BY VELOCITY-COMPENSATED UNCOMPENSATED DIFFERENCE IMAGES [J].
AXEL, L ;
MORTON, D .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (01) :31-34
[3]   RESPIRATORY ORDERED PHASE ENCODING (ROPE) - A METHOD FOR REDUCING RESPIRATORY MOTION ARTIFACTS IN MR IMAGING [J].
BAILES, DR ;
GILDERDALE, DJ ;
BYDDER, GM ;
COLLINS, AG ;
FIRMIN, DN .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (04) :835-838
[4]   MEASUREMENT OF FLOW WITH NMR IMAGING USING A GRADIENT PULSE AND PHASE DIFFERENCE TECHNIQUE [J].
BRYANT, DJ ;
PAYNE, JA ;
FIRMIN, DN ;
LONGMORE, DB .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (04) :588-593
[5]  
CARO CG, 1978, MECHANICS CIRCULATIO
[6]  
CCARO CCG, 1987, LANCET 0704, P11
[7]   AORTIC DISTENSIBILITY IN PATIENTS WITH ISOLATED HYPERCHOLESTEROLEMIA, CORONARY-ARTERY DISEASE, OR CARDIAC TRANSPLANT [J].
DART, AM ;
LACOMBE, F ;
YEOH, JK ;
CAMERON, JD ;
JENNINGS, GL ;
LAUFER, E ;
ESMORE, DS .
LANCET, 1991, 338 (8762) :270-273
[8]   MAGNETIC-RESONANCE ANGIOGRAPHY [J].
DUMOULIN, CL ;
HART, HR .
RADIOLOGY, 1986, 161 (03) :717-720
[9]   3-DIMENSIONAL PHASE-CONTRAST ANGIOGRAPHY [J].
DUMOULIN, CL ;
SOUZA, SP ;
WALKER, MF ;
WAGLE, W .
MAGNETIC RESONANCE IN MEDICINE, 1989, 9 (01) :139-149
[10]   QUANTITATIVE MEASUREMENT OF BLOOD-FLOW USING CYLINDRICALLY LOCALIZED FOURIER VELOCITY ENCODING [J].
DUMOULIN, CL ;
SOUZA, SP ;
HARDY, CJ ;
ASH, SA .
MAGNETIC RESONANCE IN MEDICINE, 1991, 21 (02) :242-250